Cy ie gb – Parkside PWS 125 B2 Benutzerhandbuch

Seite 11

Advertising
background image

11

CY

IE

GB

from the outlet. Do not touch the cable

before it has been disconnected from

the power supply.

Risk of electric shock!

• The replacement of the plug or the con-

nection line must always be executed

by the manufacturer of the electric tool

or his/her customer service in order to

avoid any hazards.

• Only use grinding discs where the in-

dicated rotational speed is at least as

high as what has been specified on the

name plate of the device.

• Carry out a visual inspection of the

grinding disc before use. Do not use

any damaged or deformed grinding

discs. Replace any damaged or worn

grinding discs.

• Make sure that the sparks produced by

grinding do not present a danger, e.g.

reach people or ignite flammable subs-

tances.

• Always wear safety goggles, safety

gloves, respiratory protection and ear

protection when grinding, brushing and

cutting.

• Never keep the fingers between the

grinding disc and spark protection or in

close proximity to the protective hoods.

There is a risk of crushing.

• The rotating parts of the device cannot

be covered due to functional reasons.

Therefore, proceed cautiously and hold

the workpiece firmly in order to avoid

slipping which could cause your hands

to come into contact with the grinding

disc.

• The workpiece gets hot during grin-

ding. Do not touch the machined area,

allow it to cool down. There is a risk of

burning. Do not use coolants or the like.

• If you are tired or have consumed al-

cohol or tablets, do not work with the

device. Always have a break on time.

• Switch the device off and remove the

mains plug

- to loosen a blocked insertion tool,

- if the connection line is damaged or

entangled,

- in case of unusual sounds.

RESIDUAL RISKS

Even if properly operating and handling

this electric tool, some residual risks will

remain. Due to its construction and build,

this electric tool may present the following

hazards:

a) Cuts

b) Ear damage if working without ear pro-

tection.

c) Damage to your health caused by swin-

ging your hands and arms when opera-

ting the appliance for longer periods of

time or if the unit is not held or maintai-

ned properly.

d) Health injuries which result from swin-

ging hand and arm, in the event that

the device is used over a longer period

of time or is not used and maintained

properly.

Warning! During operation, this

electric tool generates an electro-

magnetic field which, under certain

circumstances, may impair the

functionality of active or passive

medical implants. To reduce the risk

of serious or lethal injuries, we re-

commend that persons with medical

implants consult their doctor and the

manufacturer of their medical im-

plant before operating the machine.

Advertising