Compressed-air mini grinder pdms a1 introduction – Parkside PDMS A1 Benutzerhandbuch

Seite 25

Advertising
background image

22

PDMS A1

GB

COMPRESSED-AIR MINI
GRINDER PDMS A1

Introduction

Congratulations on the purchase of your

new appliance. You have selected a high-
quality product. The operating instructions

are part of this product. They contain important in-
formation about safety, use and disposal.
Before using the product, familiarise yourself with all
operating and safety instructions. Use this product
only as described and only for the specifi ed areas
of application. Please also pass these operating
instructions on to any future owner(s).

Proper use

The compressed air mini grinder (hereinafter re-
ferred to as "Appliance" / grinder) is suitable for
grinding and deburring of metal. Any other uses of
or modifi cations to the appliance are deemed to
be improper usage and may result in serious physi-
cal injury. Not for commercial use.

Features

Clamping chuck
Compressed air mini grinder
Speed setting wheel
Compressed air hose
Threaded connector 1/4“
Installation spanner SW 9
Tefl on tape
Threaded connector 1/4“
Mini compressed air oiler
Female threaded connector 1/4“
Crosshead screw for oil fi ller opening
Compressed air connector plug
Threaded nipple 1/4“
Oil bottle
Whetstone

Package contents

1 compressed air mini grinder
2 installation spanners SW 9
1m Tefl on tape
1 compressed air oil container
1 compressed air connector plug
1 mini compressed air oiler
10 whetstones
1 transport case with inspection window
1 operating instructions

Technical details

Rotational speed:

0 - 54000 rpm

Working pressure:

max. 6.3 bar

Chuck capacity

3.2 mm

Airfl ow:

max. 200 l/min

Air inlet:

1/4“

Housing material:

Aluminium

Weight
(compressed air mini
grinder with hose):

approx. 175 g

Sound pressure level: 79.0 dB(A)
Sound power level:

90.0 dB(A)

Uncertainty K:

3 dB

Measured values determined in
accordance with:

ISO 15744, ISO 4871

Wear ear protection!

Vibration emission value = 0.744 m/s

2

Uncertainty K = 0.043 m/s

2

Measured values determined
in accordance with: ISO 28927-12,

EN 12096

WARNING!

IB_43105_PDMSA1_LB1.indb 22

IB_43105_PDMSA1_LB1.indb 22

14.05.14 11:13

14.05.14 11:13

Advertising