Trouble shooting, Gb ie cy – Parkside PNTS 1300 C3 Benutzerhandbuch

Seite 12

Advertising
background image

12

GB IE

CY

Trouble shooting

Problem

Possible cause

Fault correction

Device does not start

Mains voltage is not present

Check plug socket, cable, line,

plug and fuse, where appropri-

ate, repair through electrical

specialist

Defective on/off switch

(

3)

Repair through customer service

Worn carbon brushes

Defective motor

Low or lack of suction

Hose system (

13/14) or

jets (

18/19) blocked

Remove obstructions and block-

ages

Suction pipe (

12) assem-

bled incorrectly

Assemble suction pipe correctly

Container (

6) open

Close container

Container (

6) full

Empty container

Filter (

15/16/17) full or

clogged

Empty, clean or replace filter

Float in filter basket (

21)

incorrectly positioned (e.g.

due to jerky movements)

Switch off the equipment so the

ball drops then switch on again

Float in the filter basket

(

21) faulty

Repair by Customer Care

Float does not switch

the appliance off

Float in the filter basket

(

21) does not move

Release float

Float in the filter basket

(

21) faulty

Repair by Customer Care

Dust or dirt is blow

out of the device

Filter (

15/16/17) is not

or not correctly assembled

Use missing filters or check the

correct position of the filter

Advertising