Extreme Networks 12800 Series Benutzerhandbuch

Seite 69

Advertising
background image

Grounding the BlackDiamond 12800 Series Chassis

BlackDiamond 12800 Series Switches Hardware Installation Guide

69

To ground the chassis:

1

Locate the grounding point on the back of the chassis (

Figure 38

and figure)).

Figure 38: Back of BlackDiamond 12804 Chassis

Figure 39: Back of BlackDiamond 12802 Chassis

2

Strip 0.5-inch (1.2-cm) of insulation from the stranded copper wire cable.

3

Insert the stripped wire into the cable lug.

CAUTION

Be sure that no copper is visible between the lug and the cable insulation.

4

Crimp the lug onto the cable according to the manufacturer’s specifications.

5

Insert the screws through the lug and into the grounding point on the back of the chassis.

6

Connect the other end of the wire to a known reliable earth ground point at your site.

EX_128A

Grounding point

PSU

/

fan

controllers

Fan tray

Grounding
point

PSU/fan controller

module

Power

supplies

BD_142A