Temperature display, Pocket lamp, Automatic switch-off – Powerfix PBUH 1.5 A1 Benutzerhandbuch

Seite 8: Gb ie

Advertising
background image

5

PBUH 1.5 A1

GB

IE

Measurement of constructional material or wood moisture

Switch the appliance on by pressing the ON/SET button.

Before taking the fi rst measurement, check that the appliance is functioning
correctly. For this, use the test aid . On the test aid there are four
measurement points marked as and .

Press the measuring pins on the measurement points . All measurement
lines on the display begin to blink.

Now press the measuring pins on the measurement points . The measuring
lines on the display should now be showing 19 % (+/- 1 %).

When you arrive at the given value in both tests, the appliance is ready for use.

Press the measuring pins into the material to be tested. The measurement
lines on the display show the moisture content.

To read the result for fi rewood, cardboard and construction timber, use the
left scale with the symbol .

To read the results for mortar, concrete and plaster, use the right scale with
the symbol

.

If the measured value exceeds the maximum values of 2 % resp. 44 %, the
measurement lines start to blink.

To minimise measurement errors, carry out comparative measurements at
several locations.

Temperature Display

The temperature is indicated at the top of the display .

Press and hold the ON/SET button for 3 seconds to toggle between
Celsius and Fahrenheit.

Pocket lamp

Press and hold the button for 3 seconds to switch the LED on.

Press the button once again to switch the LED off .

Automatic switch-off

The appliance switches itself off automatically after approx. 30 seconds without
button activation. The automatic switch off is disabled when the LED is
switched on.

Buch_75094_LB3.indb 5

14.06.12 15:56

Advertising
Dieses Handbuch ist für die folgenden Produkte bezogen werden: