MAINS OPERATION & RESULTING TEMPERATURE

MAINS OPERATION & RESULTING TEMPERATURE

The following tables allow determining power supply and cabling requirements.

The power drawn from the mains network is converted into output power to feed the connected
loudspeaker systems and into heat. The difference between power consumption and dispensed power
is called power dissipation (Pd). The amount of heat resulting from power dissipation might remain
inside of a rack-shelf and needs to be diverted using appropriate measures. The following table is
meant as auxiliary means for calculating temperatures inside of a rack-shelf system/cabinet and the
ventilation efforts necessary.
The column „Pd“ lists the leakage power in relation to different operational states. The column „BTU/hr“
lists the dispensed heat amount per hour.

CP 1200

U

mains

[V]

I

mains

[A]

P

mains

[W]

P

out

[W]

Pd

(5)

[W]

BTU/hr

(1)

idle

230V

0,37

42

-

42

143

Max. Output Power @ 8Ω

(1)

230V

4,6

743

2 x 240

263

895

Max. Output Power @ 4Ω

(1)

230V

7,5

1310

2 x 400

510

1740

1/3 Max. Output Power @ 4Ω

(1)

230V

4,7

774

2 x 133

508

1735

1/8 Max. Output Power @ 4Ω

(1)

230V

3,2

496

2 x 50

396

1350

1/8 Max. Output Power @ 4Ω

(2)

230V

3,0

460

2 x 50

360

1230

1/8 Max. Output Power @ 4Ω

(2),(4)

254V

3,4

600

2 x 63

426

1455

Normal Mode (-10dB) @ 4Ω

(1)

230V

3,0

450

2 x 40

370

1260

Rated Output Power (0dB) @ 4Ω

(1)

230V

6,6

1152

2 x 300

552

1885

Alert (Alarm) Mode (-3dB) @ 4Ω

(1)

230V

5,0

828

2 x150

528

1800

Max. Output Power @ 2Ω

(1)

230V

11,6

2210

2 x 600

1010

3445

1/8 Max. Output Power @ 2Ω

(1)

230V

5,0

820

2 x 75

670

2285

1/8 Max. Output Power @ 2Ω

(2)

230V

4.7

755

2 x 75

605

2065

(1) Sine Modulation (1kHz) (2) VDE-Noise (3) 1BTU = 1055.06J = 1055.06Ws

(4) 10% Mains Over Voltage (5) Pd = Leakage Power

The following factors allow direct proportional calculation of the mains current Imain for different mains
supply voltages: 100V = 2.3; 120V = 1.9; 240V = 0.96