Technical data

Dimensions of the recess

Height

mm 600

Width

mm 560

Depth

mm 550

Oven

Height

mm 335

Width

mm 395

Depth

mm 400

Oven capacity

53 l

This appliance can be connected to the below listed

ceramic hobs:

Type:

ZVD 868

(with 2 double-circuit cooking zones)

Maximum power absorbed:

7,6 kW

Power supply voltage

(50 Hz) 230 V

Type: ZK 630 L - ZK 630 F
(with 2 double-circuit cooking zones)
Maximum power absorbed

7,6 kW

Power supply voltage

(50 Hz) 230 V

Type: ZC 6695
(with 1 double-circuit cooking zone)
Maximum power absorbed

6,4 kW

Power supply voltage

(50 Hz) 230 V

Type: ZC 6675
(without double-circuit cooking zone)
Maximum power absorbed

5,8 kW

Power supply voltage

(50 Hz) 230 V

Maximum Total Power Rate
Oven + ceramic hob

9,675 kW

Heating element ratings

Bottom heating element

1000 W

Top Heating element

800 W

Full oven (Top+Bottom)

1800 W

Fan cooking

2000 W

Grill

1650 W

Oven light

25 W

Hot air fan motor

25 W

Cooling fan motor

25 W

Total rating

2075 W

Operating voltage (50 Hz)

230 V

Instructions for the Installer

The instructions given below are designed

specifically for a qualified installer and should

aid him or her to perform all installation,

adjustment, and maintenance operations with

absolute precision and in compliance with all

current legislation and regulations. We

strongly recommend that all operations for

the installation of your cooker be carryed out

by Qualified Personnel in accordance with

existing rules and regulations.

Electrical connection

Prior to making the electrical connection, make sure that:

— the protection fuse and the domestic wiring

system are suitable to carry the total electric load of the

oven (see rating plate);

— your domestic wiring system has an efficient

earth connection in compliance with rules and laws in

force;

— the wall socket or the omnipole switch used for

the electrical connection can easily be reached after the

oven is built in.

This appliance is delivered without an electric supply cable,

therefore, you will have to fit to it a supply cable with standard

plug, suitable for the total electric load shown on the rating plate.

The plug is to be inserted into a suitable wall socket. If you

require a direct connection to the electric network (mains), it will

be necessary to fit between the appliance and the mains an

omnipole switch, with a minimum gap between contacts of 3

mm, suitable for the required load and in compliance with rules

in force. The green & yellow ground wire must not be interrupted

by the switch, and should be 2-3 cm longer than the phase and

neutral wires. The supply cable must in all cases be laid out in

such a way as to ensure that it does not reach at any given

point a temperature 50°C higher than the ambient temperature.

Suitable power supply cables are the following types,

considering the respective necessary section of cable: H07 RN-

F, H05 RN-F, H05 RR-F, H05 VV-F, H05 V2V2-F (T90), H05

BB-F.

Advertising