Größen
ØDN Kräfte in lbf (N)
Drehmomente in ft-lb (Nm)
Fx
Fy
Fz
ΣF
Mx
My
Mz
ΣM
50-32-160
32
142 (630) 135 (600)
166 (740)
261 (1,160) 568 (770)
391 (530)
443 (600)
826 (1,120)
50-32-200
32
142 (630) 135 (600)
166 (740)
261 (1,160) 568 (770)
391 (530)
443 (600)
826 (1,120)
50-32-250
32
142 (630) 135 (600)
166 (740)
261 (1,160) 568 (770)
391 (530)
443 (600)
826 (1,120)
50-32-315
32
142 (630) 135 (600)
166 (740)
261 (1,160) 568 (770)
391 (530)
443 (600)
826 (1,120)
65-40-160
40
173 (770) 157 (700)
198 (880)
308 (1,370) 664 (900)
465 (630)
546 (740)
981 (1,330)
65-40-200
40
173 (770) 157 (700)
198 (880)
308 (1,370) 664 (900)
465 (630)
546 (740)
981 (1,330)
65-40-250
40
173 (770) 157 (700)
198 (880)
308 (1,370) 664 (900)
465 (630)
546 (740)
981 (1,330)
65-40-315
40
173 (770) 157 (700)
198 (880)
308 (1,370) 664 (900)
465 (630)
546 (740)
981 (1,330)
80-50-160
50
236 (1,050) 214 (950)
259 (1,150) 409 (1,820) 723 (980)
516 (700)
590 (800)
1,069 (1,450)
80-50-200
50
236 (1,050) 214 (950)
259 (1,150) 409 (1,820) 723 (980)
516 (700)
590 (800)
1,069 (1,450)
80-50-250
50
236 (1,050) 214 (950)
259 (1,150) 409 (1,820) 723 (980)
516 (700)
590 (800)
1,069 (1,450)
80-50-315
50
236 (1,050) 214 (950)
259 (1,150) 409 (1,820) 723 (980)
516 (700)
590 (800)
1,069 (1,450)
100-65-160
65
292 (1,300) 270 (1,200) 330 (1,470) 517 (2,300) 774 (1,050)
568 (770)
620 (840)
1,143 (1,550)
100-65-200
65
292 (1,300) 270 (1,200) 330 (1,470) 517 (2,300) 774 (1,050)
568 (770)
620 (840)
1,143 (1,550)
100-65-250
65
292 (1,300) 270 (1,200) 330 (1,470) 517 (2,300) 774 (1,050)
568 (770)
620 (840)
1,143 (1,550)
100-65-315
65
292 (1,300) 270 (1,200) 330 (1,470) 517 (2,300) 774 (1,050)
568 (770)
620 (840)
1,143 (1,550)
125-80-160
80
355 (1,580) 324 (1,440) 393 (1,750) 620 (2,760) 826 (1,120)
590 (800)
671 (910)
1,217 (1,650)
125-80-200
80
355 (1,580) 324 (1,440) 393 (1,750) 620 (2,760) 826 (1,120)
590 (800)
671 (910)
1,217 (1,650)
125-80-250
80
355 (1,580) 324 (1,440) 393 (1,750) 620 (2,760) 826 (1,120)
590 (800)
671 (910)
1,217 (1,650)
125-80-315
80
355 (1,580) 324 (1,440) 393 (1,750) 620 (2,760) 826 (1,120)
590 (800)
671 (910)
1,217 (1,650)
125-80-400
80
355 (1,580) 324 (1,440) 393 (1,750) 620 (2,760) 826 (1,120)
590 (800)
671 (910)
1,217 (1,650)
125-100-200 100
472 (2,100) 427 (1,900) 528 (2,350) 825 (3,670) 907 (1,230)
649 (880)
752 (1,020) 1,342 (1,820)
125-100-250 100
472 (2,100) 427 (1,900) 528 (2,350) 825 (3,670) 907 (1,230)
649 (880)
752 (1,020) 1,342 (1,820)
125-100-315 100
472 (2,100) 427 (1,900) 528 (2,350) 825 (3,670) 907 (1,230)
649 (880)
752 (1,020) 1,342 (1,820)
125-100-400 100
472 (2,100) 427 (1,900) 528 (2,350) 825 (3,670) 907 (1,230)
649 (880)
752 (1,020) 1,342 (1,820)
150-125-250 125
562 (2,500) 504 (2,240) 618 (2,750) 978 (4,350) 1,084 (1,470) 774 (1,050)
981 (1,330) 1,578 (2,140)
150-125-315 125
562 (2,500) 504 (2,240) 618 (2,750) 978 (4,350) 1,084 (1,470) 774 (1,050)
981 (1,330) 1,578 (2,140)
150-125-400 125
562 (2,500) 504 (2,240) 618 (2,750) 978 (4,350) 1,084 (1,470) 774 (1,050)
981 (1,330) 1,578 (2,140)
200-150-250 150
708 (3,150) 641 (2,850) 787 (3,500) 1,236 (5,500) 1,291 (1,750) 907 (1,230)
1,069 (1,450) 1,888 (2,560)
200-150-315 150
708 (3,150) 641 (2,850) 787 (3,500) 1,236 (5,500) 1,291 (1,750) 907 (1,230)
1,069 (1,450) 1,888 (2,560)
200-150-400 150
708 (3,150) 641 (2,850) 787 (3,500) 1,236 (5,500) 1,291 (1,750) 907 (1,230)
1,069 (1,450) 1,888 (2,560)
Checkliste für die die Saugrohre
Kennlinienreferenz
VORSICHT:
Ändern Sie den Durchsatz über das Regelventil in der Druckleitung. Drosseln Sie den Durchfluss nie von
der Saugseite. Dies kann zu einer verringerten Leistung, unerwarteter Hitzebildung und Schäden an den
Geräten führen.
Die verfügbare Haltedruckhöhe (NPSH
A
) muss immer die notwendige Haltedruckhöhe (NPSH
R
) übersteigen, wie in der
Pumpenkennlinie des Herstellers gezeigt.
Checkliste für die Saugrohre
Prüfen
Erklärung/Bemerkung
Kontrolliert
Prüfen Sie, dass der Abstand zwischen dem Einlassflansch der
Pumpe und dem nächsten Bogen mindestens das Fünffache des
Rohrdurchmessers beträgt.
Dies minimiert die Gefahr von Kavitation
aufgrund von Turbulenzen am Saugeinlass der
Pumpe.
Abbildungen dazu finden Sie in den
Beispielabschnitten.
Installation
32