Checkliste für die die saugrohre – Goulds Pumps IC - IOM Benutzerhandbuch

Seite 34

Advertising
background image

Größen

ØDN Kräfte in lbf (N)

Drehmomente in ft-lb (Nm)

Fx

Fy

Fz

ΣF

Mx

My

Mz

ΣM

50-32-160

32

142 (630) 135 (600)

166 (740)

261 (1,160) 568 (770)

391 (530)

443 (600)

826 (1,120)

50-32-200

32

142 (630) 135 (600)

166 (740)

261 (1,160) 568 (770)

391 (530)

443 (600)

826 (1,120)

50-32-250

32

142 (630) 135 (600)

166 (740)

261 (1,160) 568 (770)

391 (530)

443 (600)

826 (1,120)

50-32-315

32

142 (630) 135 (600)

166 (740)

261 (1,160) 568 (770)

391 (530)

443 (600)

826 (1,120)

65-40-160

40

173 (770) 157 (700)

198 (880)

308 (1,370) 664 (900)

465 (630)

546 (740)

981 (1,330)

65-40-200

40

173 (770) 157 (700)

198 (880)

308 (1,370) 664 (900)

465 (630)

546 (740)

981 (1,330)

65-40-250

40

173 (770) 157 (700)

198 (880)

308 (1,370) 664 (900)

465 (630)

546 (740)

981 (1,330)

65-40-315

40

173 (770) 157 (700)

198 (880)

308 (1,370) 664 (900)

465 (630)

546 (740)

981 (1,330)

80-50-160

50

236 (1,050) 214 (950)

259 (1,150) 409 (1,820) 723 (980)

516 (700)

590 (800)

1,069 (1,450)

80-50-200

50

236 (1,050) 214 (950)

259 (1,150) 409 (1,820) 723 (980)

516 (700)

590 (800)

1,069 (1,450)

80-50-250

50

236 (1,050) 214 (950)

259 (1,150) 409 (1,820) 723 (980)

516 (700)

590 (800)

1,069 (1,450)

80-50-315

50

236 (1,050) 214 (950)

259 (1,150) 409 (1,820) 723 (980)

516 (700)

590 (800)

1,069 (1,450)

100-65-160

65

292 (1,300) 270 (1,200) 330 (1,470) 517 (2,300) 774 (1,050)

568 (770)

620 (840)

1,143 (1,550)

100-65-200

65

292 (1,300) 270 (1,200) 330 (1,470) 517 (2,300) 774 (1,050)

568 (770)

620 (840)

1,143 (1,550)

100-65-250

65

292 (1,300) 270 (1,200) 330 (1,470) 517 (2,300) 774 (1,050)

568 (770)

620 (840)

1,143 (1,550)

100-65-315

65

292 (1,300) 270 (1,200) 330 (1,470) 517 (2,300) 774 (1,050)

568 (770)

620 (840)

1,143 (1,550)

125-80-160

80

355 (1,580) 324 (1,440) 393 (1,750) 620 (2,760) 826 (1,120)

590 (800)

671 (910)

1,217 (1,650)

125-80-200

80

355 (1,580) 324 (1,440) 393 (1,750) 620 (2,760) 826 (1,120)

590 (800)

671 (910)

1,217 (1,650)

125-80-250

80

355 (1,580) 324 (1,440) 393 (1,750) 620 (2,760) 826 (1,120)

590 (800)

671 (910)

1,217 (1,650)

125-80-315

80

355 (1,580) 324 (1,440) 393 (1,750) 620 (2,760) 826 (1,120)

590 (800)

671 (910)

1,217 (1,650)

125-80-400

80

355 (1,580) 324 (1,440) 393 (1,750) 620 (2,760) 826 (1,120)

590 (800)

671 (910)

1,217 (1,650)

125-100-200 100

472 (2,100) 427 (1,900) 528 (2,350) 825 (3,670) 907 (1,230)

649 (880)

752 (1,020) 1,342 (1,820)

125-100-250 100

472 (2,100) 427 (1,900) 528 (2,350) 825 (3,670) 907 (1,230)

649 (880)

752 (1,020) 1,342 (1,820)

125-100-315 100

472 (2,100) 427 (1,900) 528 (2,350) 825 (3,670) 907 (1,230)

649 (880)

752 (1,020) 1,342 (1,820)

125-100-400 100

472 (2,100) 427 (1,900) 528 (2,350) 825 (3,670) 907 (1,230)

649 (880)

752 (1,020) 1,342 (1,820)

150-125-250 125

562 (2,500) 504 (2,240) 618 (2,750) 978 (4,350) 1,084 (1,470) 774 (1,050)

981 (1,330) 1,578 (2,140)

150-125-315 125

562 (2,500) 504 (2,240) 618 (2,750) 978 (4,350) 1,084 (1,470) 774 (1,050)

981 (1,330) 1,578 (2,140)

150-125-400 125

562 (2,500) 504 (2,240) 618 (2,750) 978 (4,350) 1,084 (1,470) 774 (1,050)

981 (1,330) 1,578 (2,140)

200-150-250 150

708 (3,150) 641 (2,850) 787 (3,500) 1,236 (5,500) 1,291 (1,750) 907 (1,230)

1,069 (1,450) 1,888 (2,560)

200-150-315 150

708 (3,150) 641 (2,850) 787 (3,500) 1,236 (5,500) 1,291 (1,750) 907 (1,230)

1,069 (1,450) 1,888 (2,560)

200-150-400 150

708 (3,150) 641 (2,850) 787 (3,500) 1,236 (5,500) 1,291 (1,750) 907 (1,230)

1,069 (1,450) 1,888 (2,560)

Checkliste für die die Saugrohre

Kennlinienreferenz

VORSICHT:
Ändern Sie den Durchsatz über das Regelventil in der Druckleitung. Drosseln Sie den Durchfluss nie von
der Saugseite. Dies kann zu einer verringerten Leistung, unerwarteter Hitzebildung und Schäden an den
Geräten führen.

Die verfügbare Haltedruckhöhe (NPSH

A

) muss immer die notwendige Haltedruckhöhe (NPSH

R

) übersteigen, wie in der

Pumpenkennlinie des Herstellers gezeigt.

Checkliste für die Saugrohre

Prüfen

Erklärung/Bemerkung

Kontrolliert

Prüfen Sie, dass der Abstand zwischen dem Einlassflansch der

Pumpe und dem nächsten Bogen mindestens das Fünffache des

Rohrdurchmessers beträgt.

Dies minimiert die Gefahr von Kavitation

aufgrund von Turbulenzen am Saugeinlass der

Pumpe.
Abbildungen dazu finden Sie in den

Beispielabschnitten.

Installation

32

Model IC, ICI, ICH, ICIH Montage-, Betriebs- und Wartungshandbuch

Advertising