Quick Start Guide Commissioning/Mounting IWL3000 series

1

120125_

Q

UICK

S

TART

GUIDE

IWL3000_DE_EN

DZ-HAND-91055-0

V1.0

© ads-tec GmbH • Raiffeisenstr.14 • 70771 Leinfelden-Echterdingen

1. Scope of delivery

3. Connceting the device

5. Configuration

1 x Industrial Wireless LAN Access Point

1 x 3 pol. connector

2 x 4 pol. connector

1 x Rail mounting holder

2 x M4 x 6 Pan Head screw + 2 x M4 washer + 2 x Disk washer

4 x rubber feet

1 xEthernet cable 1m

1 x Quick Start Guide Commissioning/Mounting IWL3000 series

1 x GNU General Public License

Warning:

Any installation works on the device are only
permitted if the power supply is switched off, and
if handling the device is safe.

Note:

Please observe applicable security measures
when handling electronic components sensitive
to electrostatic charges.

(DIN EN61340-5-1 /
DIN EN 61340-5-2).

2.1 Table mounting

Remove the protective strip from the rubber feet and fix them
to the marked locations.

2.2 Wall mounting

The unit can be mounted alternatively via VESA 75 standard at a
suitable mounting surface.

2.3.Rail mounting

Install the supplied rail mounting holder in the following
order:

WasherRail mounting holderDisk washerPan Head
screw to the device.

The unit is set at an angle from the top of the rail (1) and is
fixed by gently pushing it to the bottom (2). The unit must
engage significantly in the rail.

To release the unit from the DIN rail, proceed in reverse
order.

Note:

When installing the rail mounting holder, there is
danger of injury from sharp edges.

Note:

Be carfeful not to damage the rail mounting
holder while removing it.

3.1. Power supply conncetion

The power for this device can be supplied by a 24V DC
(7…36V) (3 pin plug). The corresponding connector is
included in the scope of delivery. Connect the device
with a suitable power supply unit.

Once the power supply is connected to the device, the
PWR LED is solid green.

(Front view)

4.1. Antenna indication IWL3000 series

The device offers 1 (IWL3210) or 2 (IWL3220) WLAN
modules, depending on the variant. The following
graphic shows the indication of the respective
antenna.

(Top view)

(bottom view)

PIN-

NUMBER

SIGNAL

NAME

1

24V DC

2

GND

3

PE

5.1. RJ45 network cable connection

For initial commissioning it is essential to establish a
connection between this device and a PC. Connect the device
with a PC.

5.2. Configuration of the PC-LAN-Network adapter

Open the Properties tab of the used network adapter.

Use following IP address

Access to the device is only enabled once the following
parameters have been entered:

IP address: 192.168.0.

100

Subnet mask: 255.255.255.0

(The last section of digits must represent a number
between 1 and 253; the value “

100

” has been selected in

the example)

5.3. Access the webinterface

Start your web browser in order to open the web interface
of this device. Now enter the following IP address into the
address line of your browser:

http://192.168.0.254

5.4. Login

In the Login prompt window, the default settings must be
entered. The default settings, as delivered to the
customer, are:

User name: admin

Password: admin

Confirm your entry by using OK. Now, the device web
interface will appear.

Note:
If you are using a Proxy, it has to be deactivated
if neccessary.

Note:
We would recommend to make use of our
website contents (www.ads-tec.de) in order to
ensure an optimised data quality and to be
quickly and comprehensively informed of any
technical modification.

2. Mounting

4. Antenna indication IWL3000 series

Advertising