4.2 Hysteresis
The respective output switches when the set switching point is reached and switches back when
the pressure drops below the switch-back point. The switch-back point is determined by the set
hysteresis (switch-back point = switching point minus hysteresis).
Abbreviations:
= hysteresis
4.3 Switching direction
With the switching direction the switching function gets set as normaly open or normaly closed.
Abbreviations:
= Switching direction
= N/O function
= N/C function
4.3 Switch-on delay
Time in milliseconds which must elapse, once the switching point has been reached or exceeded,
before switching will occur.
Abbreviations:
= switch-on delay [ms]
4.4 Switch-off delay
Time in milliseconds which must elapse, once the pressure has fallen below the particular switch-
back point, before switching will occur.
Abbreviations:
= switch-off delay [ms]