Electrical installation – Lenze CPC 5100 Benutzerhandbuch
Seite 54

Electrical installation
Installing the expansion cards
l
54
LDCDS−CPC5100 DE/EN 1.1
How to mount the expansion cards:
1. Disconnect the mains cable
0 and all external connections.
2. Remove the device from the control cabinet wall and place it on a table horizontally
with the screws
1 facing upwards.
3. Open the housing:
– Loosen the two screws
1.
– Carefully remove the housing cover
2 forward.
4. If the device is equipped with a UPS, disconnect the battery pack (
¶ 55).
5. Remove the retention clip
3:
– Disconnect the fan connector
4.
– Loosen the two screws
5 and turn the retention clip upwards.
6. Insert the expansion card:
– Remove the bracket of the desired slot
6.
– Slightly press the expansion card into the socket connector on the mainboard from
the top. In doing this, the mainboard may not be bent!
– Make sure that the card is positioned in the socket connector correctly.
– Tighten the bracket of the expansion card.
7. Mount the retention clip
3:
– Turn the retention clip downwards and secure it by means of the screw
5.
– Plug in the fan connector
4.
8. Securing the expansion card with a plastic bar
– For procedure see the following illustration.
– Only secure the expansion card slightly; it may not be bent!
– The plastic bar and locating screws are included in the scope of supply, but can
also be ordered separately.
CPC5100−005
9. If the device is equipped with a UPS, connect the battery pack (
¶ 55).
10. Close the housing:
– Carefully place the housing cover
2 on the housing.
– Tighten the two screws
1.