Electrical installation 5 – Lenze MC-PBS Benutzerhandbuch
Seite 37
Advertising

Electrical installation
LDCDS−MC−PBx DE/EN 3.0
37
l
H1_E_INST−PBS_Uebrate_LtgLaenge
Specification of the transmission cable
)
Note!
Only use cables complying with the listed specifications of the PROFIBUS user
organisation.
Field
Values
Specific resistance
135 ... 165
W
/km, (f = 3 ... 20 MHz)
Capacitance per unit length
£
30 nF/km
Loop resistance
< 110
W
/km
Core diameter
> 0.64 mm
Core cross−section
> 0.34 mm
2
Cores
Twisted double, insulated and shielded
Baud rate / length of bus cable
Baud rate [kBit/s]
Length [m]
9.6 − 93.75
1200
187.5
1000
500
400
1500
200
3000 − 12000
100
Advertising
Dieses Handbuch ist für die folgenden Produkte bezogen werden: