Configuration
Windows XP
LDCDS−MC−PNx DE/EN 2.0
44
l
H1_konfig−Einsatz_MC_PBx_CE_Hin
2. Assign the bus−specific firmware file to the communication channel 0 (CH#0):
– Go to the object tree and open the Active Devices folder and the (sub) folder of the
communication card (e.g. cifX0 ( )) you want to configure.
– Click the communication channel you want to assign to a firmware file. The
respective dialog page is displayed.
– Go to the Downloads (Modules) area, click the Add button and select the firmware
file (*.nxf) in the following menu.
– Confirm the selection with OK. The file path and the name of the firmware file are
displayed in the "File" list.
– Click the Apply button.
3. Exit the "cifX Driver Setup Utility" application via the File
W Quit menu.
)
Note!
Only for MC−PNC (Controller):
ƒ
Configure the bus via the host application or the bus configurator
"SyCon.net".
Only for MC−PND (Device):
ƒ
Configure the bus via the warm start parameters in the "cifX Driver Setup
Utility". Further information can be obtained from the online help of the
"cifX Driver Setup Utility" and the documentation of Hilscher.