Electrical installation – Lenze MDFQA Benutzerhandbuch

Seite 27

Advertising
background image

Electrical installation

Design including a connector

4

ASPL 33.0007 DE/EN 1.0

27

l

H1_E_INST−fuss_elektr.typenschild

Sin/cos absolute value encoder with EnDat interface (external view of poles)

Pin

Designation

Meaning

M23

1

UP sensor

Supply UP sensor

2
3

Not assigned

4

0 V sensor

0 V sensor supply

5
6

+ KTY
− KTY

KTY thermal detector

7

+ U

B

Supply + / +VCC ENP

1)

8
9

Clock pulse
Clock pulse

Clock pulse EnDat interface
Clock pulse inverse EnDat
interface

10

GND

Earth

11

Shield

Shield for housing of encoder

12
13

B
B

Track B
Track B inverse

14

Data

Data EnDat interface

15
16

A
A

Track A
Track A inverse

17

Data

Data inverse EnDat interface

1)

Only for versions with electronic nameplate ENP.

*

At times, older documents also stated plug sizes of 1.0 (M23) and 1.5 (M40).