Feedback system, 4electrical installation – Lenze MDFQA Benutzerhandbuch
Seite 30

Electrical installation
Design including a terminal box
ASPL 33.0007 DE/EN 1.0
30
l
H1_E_INST−fuss_elektr.typenschild
Feedback system
Resolver
Terminal
Designation
Meaning
B1
B2
+ Ref
− Ref
Transformer windings (reference
windings)
B3
+ VCC ENP
Supply: electronic nameplate
1)
B4
B5
+ Cos
− Cos
Stator winding cosine
B6
B7
+ Sin
− Sin
Stator winding sine
B8
Not assigned
R1
R2
+ KTY
− KTY
KTY thermal detector
1)
Only for versions with electronic nameplate ENP.
Incremental encoder / sin/cos absolute value encoder with Hiperface
Terminal
Designation
Meaning
B1
B2
+ U
B
GND
Supply +
Earth
B3
B4
A
A
Track A / + COS
Track A inverse / − COS
B5
B6
B
B
Track B / + SIN
Track B inverse / − SIN
B7
B8
Z
Z
Zero track / + RS485
Zero track inverse / − RS485
B10
Shield − housing
Incremental encoder − shield
R1
R2
+ KTY
− KTY
Temperature sensor KTY +
Temperature sensor KTY −