2 rated data, Rated data, Technical data – Lenze ELCAFHIxxx4E34NNPM Highline Benutzerhandbuch
Seite 61: 2 rated data input data

Technical data
Rated data
l
61
EDKLCFH3024−EPM DE/EN 2.0
2.2
Rated data
Input data
Basis of the data
Mains
Voltage
U
LN
[V]
Voltage range
U
LN
[V]
Frequency range
f [Hz]
3/PE AC
400
320 − 0 % ... 440 + 0 %
45 − 0 % ... 65 + 0 %
3/PE AC
500
400 − 0 % ... 550 + 0 %
45 − 0 % ... 65 + 0 %
Cyclic mains switching
Type
ELCAFHI7514
Max. 5 switchings / 5 minutes
ELCAFHI1524
ELCAFHI3024
Voltage
Frequency
Current (T
a1
)
1)
Current (T
a2
)
2)
Number
of phases
Typ
[V]
[Hz]
[A]
[A]
ELCAFHI7514
400/500
50/60
3.3/2.6
2.1/1.6
3
ELCAFHI1524
400/500
50/60
5.5/4.4
3.4/2.8
3
ELCAFHI3024
400/500
50/60
9.0/7.9
5.6/4.9
3
1)
Ta1 = max. 40 °C ambient temperature during operation
2)
Ta2 = max. 55 °C ambient temperature during operation
Supply voltage for control electronics of the controller
(safely separated power supply unit SELV/PELV)
Typ
Voltage range U
DC
[V DC]
Current consumption at + 24 V DC [A]
Min.
1)
Max.
2)
ELCAFHI7514
+ 24
(+19.2 − 0 % ... +28.8 + 0 %)
1.9
4.4
ELCAFHI1524
ELCAFHI3024
1)
No digital inputs and outputs connected
2)
All digital inputs and outputs connected