4 electrical connections 931mxnx1, Electrical connections 931mxnx1, Electrical installation – Lenze 931W Benutzerhandbuch
Seite 68

Electrical installation
Electrical connections 931MxNx1
l
68
MA 13.1002 DE−EN DE/EN 1.1
4.4
Electrical connections 931MxNx1
X2 voltage supply
Contact pattern
Pin No. Value
Specification
1
DC 0 V (N for AC supply)
Voltage supply
2
DC + 320 V
DC voltage supply
3
AC 230 V
AC voltage supply
PE
PE
Earth and shielding
A
DC + 24 V
Brake voltage supply
B
GND
Auxiliary supply of reference
potential
C
GND
Brake enable (low active)
D
DC + 24 V
Auxiliary voltage supply
X1 RS232
Contact pattern
Pin no.
Signal
1
TxD
2
GND (ground)
3
RxD
X5 digital input, digital output (option)
Contact pattern
Pin No. Signal
Function
Specification
1
DC + 24 V
Control voltage DC + 24 V ± 10 %
2
DIN0
Digital input 0
Rated voltage
DC + 24 V
HIGH signal
DC 18 ... 30 V
LOW signal
DC 0 ... 4 V
Cycle time
Maximally 0.5
ms
3
GND
Reference potential for control voltage
4
DOUT0
Digital output 0
Output voltage
DC + 24 V
LOW signal
DC 0 ... 4 V
HIGH signal
DC 18 ... 30 V
Output current
Maximally 0.5 A
Cycle time
Maximally 0.5
ms
Short−circuit−proof