66 s sp pe ec ciiffiic ca attiio on ns s – Weidmuller IE-AR-10T-ISDN Access Router Benutzerhandbuch

Seite 20

Advertising
background image

20

6

6 S

Sp

pe

ec

ciiffiic

ca

attiio

on

ns

s

E

EM

MC

C

EN 55022:1995, Class A
EN 55024 1998
EN 61000-4-2 (ESD) 4kV/8kV
EN 61000-4-3 (radiated immunity) @AM 10V/average 80MHz - 1GHz
EN 61000-4-4 (burst) 2kV; I/O 1kV
EN 61000-4-5 (surge) 1kV
EN 61000-4-6 (conducted immunity) @10V 150kHz - 80MHz
EN 61000-4-29 (voltage variation)
EN 55011 (HF E)
conducted emissions 150kHz - 30MHz
radiated emissions 30MHz - 1GHz pp/average
radiated emissions 30MHz - 1GHz pp/qp

S

Sh

ho

oc

ck

k-- u

un

nd

d v

viib

brra

attiio

on

n--tte

es

stt

IEC 60068-2-6 sinusoidal vibrations
frequencies: 5-9 Hz, amplitude: 3.5 mm
frequencies: 9-150 Hz, acceleration: 1g
IEC 60068-2-27 shock test, half-sinusoidal
shock acceleration: 15g (operating) 30g (non operating)
shock period: 11ms

E

En

nv

viirro

on

nm

me

en

ntt--tte

es

stt

IEC 60068-2-1 & IEC 60068-2-2
operating 0°C ... 60°C
non operating -20°C ... 60°C
IEC 60068-2-30 damp heat

C

Ce

errttiiffiic

ca

attiio

on

ns

s

CE marking within the EU

UL Listed Industrial Control Equipment, certified1 for US and
Canada.

GOST R-certification (IEC standards with Russian deviations)

C

Clla

as

ss

s II D

Diiv

viis

siio

on

n 2

2

This equipment is suitable for use in Class I Division 2, Groups A,
B, C, and D or Non-Hazardous locations only.

Advertising