6
Dimensional Drawing
Power Options
Power Considerations
Voltage in the range of 10-36 VDC or 8-24 VAC must deliver current commensurate with 5-watt power
consumption. The recommended size for solid power conductors is 16-22 AWG; for stranded conduc-
tors, use 16-18 AWG. Ground is directly connected to zero volts and the chassis is isolated from zero
volts. Input connections are reverse-polarity protected.
LED Indicators
The “PWR” LED glows solid green when the switch is properly powered. To aid in troubleshooting, each
port has two LEDs. The Port 1 LED labeled “L” glows solid if a link exists, flashes to show activity and
shows data rate by color: green for 100 Mbps and yellow or 10 Mbps. The LED labeled “D” glows solid
green if full-duplex is on or is unlit when that port is operating in half-duplex mode. The LEDs of Ports
2-5 are unlabeled but work the same.
- AI8 - Multi channel signal transmitter (Seiten: 36)
- AMS400A - Universal interface device (Seiten: 44)
- CLCAR - Universal galvanically isolated signal converter (Seiten: 28)
- CNDAR - Universal galvanically isolated signal converter (Seiten: 28)
- CNDR - Universal galvanically isolated signal converter (Seiten: 24)
- DFI - 2 channel signal isolator / splitter (Seiten: 16)
- DI350 - Display instrument for control panel (Seiten: 16)
- DPAAVX - Universal glavanically isolated signal converter (Seiten: 24)
- DPADCV - Universal glavanically isolated signal converter (Seiten: 24)
- DPADMA - Universal glavanically isolated signal converter (Seiten: 24)
- DPADMV - Universal glavanically isolated signal converter (Seiten: 24)
- DPADRT - Universal glavanically isolated signal converter (Seiten: 24)
- DPAMAS - Universal glavanically isolated signal converter (Seiten: 28)
- DPAPOT - Universal glavanically isolated signal converter (Seiten: 24)
- DPARES - Universal glavanically isolated signal converter (Seiten: 24)
- DPARTD - Universal glavanically isolated signal converter (Seiten: 24)
- DPATCX - Universal glavanically isolated signal converter (Seiten: 28)
- LPD350 - Display instrument for control panel (Seiten: 12)
- LPD450F - Display instrument for outdoor use (Seiten: 20)
- PMX400HZX - Display instrument for control panel (Seiten: 28)
- PTX800A - Configurable counter and totalizer (Seiten: 48)
- RI4 - Multi channel signal transmitter / display (Seiten: 36)
- SFI - 1 channel signal isolator (Seiten: 16)
- STG - Bridge measuring transducer (Seiten: 24)
- TWI-1 - Signal isolator in 2-wire design, 1-channel (Seiten: 16)
- TWI-2 - Signal isolator in 2-wire design, 2-channel (Seiten: 16)
- UCVAR - Universal glavanically isolated signal converter (Seiten: 28)
- UCVR - Universal glavanically isolated signal converter (Seiten: 24)
- UHZAR - Universal glavanically isolated signal converter (Seiten: 24)
- UHZR - Universal glavanically isolated signal converter (Seiten: 24)
- UPIR - Analog to frequency converter (Seiten: 28)
- UPIT - Analog to frequency converter (Seiten: 28)
- URTAR - Universal glavanically isolated signal converter (Seiten: 28)
- URTR - Universal glavanically isolated signal converter (Seiten: 24)
- UTCAR - Universal glavanically isolated signal converter (Seiten: 28)
- UTCR - Universal glavanically isolated signal converter (Seiten: 28)
- XFAR - Universal glavanically isolated signal converter (Seiten: 28)
- IE-XM-RJ45 Ethernet Outlet (Seiten: 8)
- IE-AR-10T Access Router (Seiten: 22)
- Advanced Line Managed Switch (Seiten: 24)
- Advanced Line Unmanaged Switch (Seiten: 24)
- IP 67 Switch (Seiten: 22)
- IE-ARM-E-OSPF Mini Router (Seiten: 22)
- WaveLine Media Converter (Seiten: 24)