Ne214 – Baumer NE214 Benutzerhandbuch
Seite 16

NE214
16 www.baumer.com
Line 39
Assignment of function key
0
Without function
1
XP
2
P1
3
P2
4
SC
5
Σ
6
§
Line 40
Code
0000
Code not active
:
9999
Line 41
Function of batch counter
0
As Totalizer Divisor 1
1
As Totalizer Divisor 10
2
As Totalizer Divisor100
3
Count when P2 is reached
Line 42
Multiplier Batch counter (Line 41=3)
1
Default
0
Min.
999
Max.
Line 51
Baud rate
0
4800 Baud
1
2400 Baud
2
1200 Baud
3
600 Baud
Line 52
Parity
0
Even Parity
1
Odd Parity
2
No Parity
Line 53
Stop bits
0
1 Stop bit
1
2 Stop bits
Line 54
Address
00
Default
00
Min.
99
Max.
Line 61
Assignment Analog output
0
Principal counter
1
Batch counter
Line 62
Offset Analog output
0
No offset
1
Offset 2V / 4mA
Line 63
Assignment Lower analog value
0
Variable value from Line 64
1
SC
2
P1
3
P2
Line 64
Lower analog value
0
Default
-999999
Min.
999999
Max.
Line 65
Assignment Upper analog value
0
Variable value from Line 66
1
SC
2
P1
3
P2
Line 66
Upper analog value
4095
Default
-999999
Min.
999999
Max.