9 programming plan – Baumer NE213 Benutzerhandbuch
Seite 15

NE212 / NE213
www.baumer.com
15
9 Programming plan
Line 11-18
Status for Lines 1-8
0
Parameter can be altered
1
Deletion or input inhibited
2
Parameters bypassed
Line 21
Operating mode, main counting system
0
Stage preselection
1
Main preselection
2
Parallel comparison
3
P1 slave preselection
Line 22
Scaling factor, main counting system
1.0000
Minimum value
0.0001
Default value
9999.99
Maximum value
Line 23
Scaling factor, ancillary counting system
1
Minimum value
1
Default value
99
Maximum value
Line 24
Frequency track A
0
10 kHz
1
25 Hz
2
15 Hz
Line 25
Frequency track B
0
10 kHz
1
25 Hz
2
15 Hz
Line 26
Frequency batch counting input
0
10 kHz
1
25 Hz
2
15 Hz
Line 27
Operating modes, inputs
0
Track A and Up/Down
1
Differential counting A - B
2
Summation
3
A 90
° B
4
A 90
° B x 2
5
A 90
° B x 4
Line 28
Decimal point, main counting system
0
No decimal point
1
0000000.0
2
000000.00
3
00000.000
Line 29
Resetting, main counting system
0
Automatic reset and external static
1
Automatic reset and external differentiated
2
External static
3
External differentiated
Line 30
Resetting, ancillary counter
0
Automatic reset and external static
1
Automatic reset and external differentiated
2
External static
3
External differentiated
Line 31
Output P1
0.25
Continuous
0.01
Default
99.99
Maximum
Line 32
Output P2
0.25
Continuous
0.01
Default
99.99
Maximum
Line 33
Output P3
0.25
Continuous
0.01
Default
99.99
Maximum
Line 34
Acceptance of preselections P1, P2, B
0
On
1
Following
Line 35
Address for function key
0
Without function
1
XP
2
P1
3
P2
4
SC
7
Σ
5
XB
6
B1
8
§
Line 36
Function of the batch counter
0
External
1
Internal
2
Tachometer
Line 37
Pulses per unit with tachometer
1.00
Minimum value
0.01
Default value
9999.99
Maximum value
Line 38
Time basis for tachometer function
0
1 second
1
2 seconds
2
3 seconds
3
6 seconds
4
10 seconds
5
20 seconds
6
30 seconds
7
60 seconds
Line 39
Assignment output 3
0
Batch preselection output
1
Zero contact output XP
Line 40
Function input 15
0
XP Stop
1
Operating hours ON/OFF
2
Key and display hold
Line 41
Code
0000
Code not active
:
9999
Line 43
Baud rate
0
4800 Baud
1
2400 Baud
2
1200 Baud
3
600 Baud
Line 44
Parity
0
Even Parity
1
Odd Parity
2
No Parity
Line 45
Address
00
Default
00
Min.
99
Max.
Line 46
Stop bits
0
1 Stop bit
1
2 Stop bits