9 technical data, 1 general data, Technical data – Baumer GT 9 Benutzerhandbuch
Seite 26: General data

23
gt9_mb (11A2)
MB023
9
Technical data
9.1
General data
• Performance:
0.3 W (speed >5000 rpm)
• Calibration tolerance:
±5 %
• Linearity tolerance:
≤0.15 %
• Reversal tolerance:
≤0.1 %
• Superimposed ripple:
≤0.5 % peak-peak
(for τ
RC
= 0.3 ms)
≤0.25 % rms
• Temperature coefficient:
±0.05 %/K (idle)
• Armature-circuit time-constant (τ
A
):
<9 µs
• Torque:
0.35 Ncm
• Rotor moment of inertia:
0.95 kgcm
2
• Permissible armature displacement:
±0.5 mm axial
±0.1 mm radial
• Vibration resistance:
100 m/s
2
≈ 10 g
IEC 60068-2-6: 1996-05
(10 Hz ... 2 kHz)
• Shock resistance:
1,000 m/s
2
≈ 100 g
IEC 60068-2-27: 1995-03
(6 ms)
• Operating temperature:
-30°C ... +130°C
• Isolation class:
B
• Protection:
IP 00
IEC 60529
IP 44 with cover
• Climatic test:
IEC 60068-2-3, Ca (humid heat, constant)
• Weight approx.:
0.6 kg
• EMC according to:
EN 61000-6-2: 2006-03 (interference immunity)
EN 61000-6-4: 2007-09 (emitted interference)
9
Technical data