9 technical data, 1 allgemeine daten, Technical data – Baumer GT 5 Benutzerhandbuch

Seite 18: Allgemeine daten

Advertising
background image

15

gt5_mb (12A1)

MB021

9

Technical data

9.1

Allgemeine Daten

•

Performance:

0.075 W (speed >5,000 rpm)

•

Calibration tolerance:

±5%

•

Linearity tolerance:

≤0.15%

•

Reversal tolerance:

≤0.1%

•

Superimposed ripple:

≤0.7% peak-peak

(for τ

RC

= 0.3 ms)

≤0.35% rms

•

Temperature coefficient:

±0.005%/K (idle)

•

Armature-circuit time-constant (τ

A

):

<4.5 µs

•

Torque:

0.3 Ncm

•

Rotor moment of inertia:

0.05 kgcm

2

•

Permissible armature displacement:

±0.5 mm axial

±0.1 mm radial

•

Vibration resistance:

100 m/s

2

≈ 10 g

IEC 60068-2-6: 2007

(10-2,000 Hz)

•

Shock resistance:

1,000 m/s

2

≈ 100 g

IEC 60068-2-27: 2008

(6 ms)

•

Operating temperature:

-30°C...+130°C

•

Isolation class:

B

•

Protection IEC 60529:

IP 00 with cover

IP 44 with complete cover

IP 54 with complete cover and cable gland

•

Climatic tests:

IEC 60068-2-3, Ca (dump heat, constant)

•

Weight approx.:

150 g

•

EMC according to:

EN 61000-6-2: 2005 (interference immunity)

EN 61000-6-4: 2007 (emitted interference)

9

Technical data

Advertising