9 technical data, 1 allgemeine daten, Technical data – Baumer GT 5 Benutzerhandbuch
Seite 18: Allgemeine daten

15
gt5_mb (12A1)
MB021
9
Technical data
9.1
Allgemeine Daten
•
Performance:
0.075 W (speed >5,000 rpm)
•
Calibration tolerance:
±5%
•
Linearity tolerance:
≤0.15%
•
Reversal tolerance:
≤0.1%
•
Superimposed ripple:
≤0.7% peak-peak
(for τ
RC
= 0.3 ms)
≤0.35% rms
•
Temperature coefficient:
±0.005%/K (idle)
•
Armature-circuit time-constant (τ
A
):
<4.5 µs
•
Torque:
0.3 Ncm
•
Rotor moment of inertia:
0.05 kgcm
2
•
Permissible armature displacement:
±0.5 mm axial
±0.1 mm radial
•
Vibration resistance:
100 m/s
2
≈ 10 g
IEC 60068-2-6: 2007
(10-2,000 Hz)
•
Shock resistance:
1,000 m/s
2
≈ 100 g
IEC 60068-2-27: 2008
(6 ms)
•
Operating temperature:
-30°C...+130°C
•
Isolation class:
B
•
Protection IEC 60529:
IP 00 with cover
IP 44 with complete cover
IP 54 with complete cover and cable gland
•
Climatic tests:
IEC 60068-2-3, Ca (dump heat, constant)
•
Weight approx.:
150 g
•
EMC according to:
EN 61000-6-2: 2005 (interference immunity)
EN 61000-6-4: 2007 (emitted interference)
9