Technical data

9

Technical data

9.1

General data

• Performance:

0.9 W (speed >5000 rpm)

• Calibration tolerance:

±5 %

• Linearity tolerance:

≤0.15 %

• Reversal tolerance:

≤0.1 %

• Superimposed ripple:

≤0.4 % peak-peak

(for τ

RC

= 0.3 ms)

≤0.15 % rms

• Temperature coefficient:

±0.05 %/K (idle)

optional: ±0.005 %/K (idle)

• Armature-circuit time-constant (τ

A

):

<5 µs

• Torque:

0.35 Ncm

• Rotor moment of inertia:

1.95 kgcm

2

• Permissible armature displacement:

±0.5 mm axial

±0.1 mm radial

• Vibration resistance:

100 m/s

2

≈ 10 g

IEC 60068-2-6: 1996-05

(10 Hz ... 2 kHz)

• Shock resistance:

1,000 m/s

2

≈ 100 g

IEC 60068-2-27: 1995-03

(6 ms)

• Operating temperature:

-30°C ... +130°C

• Isolation class:

B

• Protection:

IP 56

IEC 60529

• Climatic test:

IEC 60068-2-3, Ca (humid heat, constant)

• Weight approx.:

1.1 kg

• EMC according to:

EN 61000-6-2: 2006-03 (interference immunity)

EN 61000-6-4: 2007-09 (emitted interference)

Advertising