9 technical data, 1 general data, Technical data – Baumer GTR 9 Benutzerhandbuch
Seite 20: General data

17
gtr9_mb (11A1)
MB024
9
Technical data
9
Technical data
9.1
General data
• Performance:
0.9 W (speed >5000 rpm)
• Calibration tolerance:
±5 %
• Linearity tolerance:
≤0.15 %
• Reversal tolerance:
≤0.1 %
• Superimposed ripple:
≤0.4 % peak-peak
(for τ
RC
= 0.3 ms)
≤0.15 % rms
• Temperature coefficient:
±0.05 %/K (idle)
optional: ±0.005 %/K (idle)
• Armature-circuit time-constant (τ
A
):
<5 µs
• Torque:
0.35 Ncm
• Rotor moment of inertia:
1.95 kgcm
2
• Permissible armature displacement:
±0.5 mm axial
±0.1 mm radial
• Vibration resistance:
100 m/s
2
≈ 10 g
IEC 60068-2-6: 1996-05
(10 Hz ... 2 kHz)
• Shock resistance:
1,000 m/s
2
≈ 100 g
IEC 60068-2-27: 1995-03
(6 ms)
• Operating temperature:
-30°C ... +130°C
• Isolation class:
B
• Protection:
IP 56
IEC 60529
• Climatic test:
IEC 60068-2-3, Ca (humid heat, constant)
• Weight approx.:
1.1 kg
• EMC according to:
EN 61000-6-2: 2006-03 (interference immunity)
EN 61000-6-4: 2007-09 (emitted interference)