10 technical data, 1 general data, Technical data – Baumer GT 7 Benutzerhandbuch
Seite 24: General data

21
gt7_mb (12A1)
MB126
10
Technical data
10.1
General data
• Performance:
GT 7.08:
0.3 W (speed >5,000 rpm)
GT 7.16:
0.6 W (speed >5,000 rpm)
• Calibration tolerance:
±5%
• Linearity tolerance:
≤0.15%
• Reversing tolerance:
≤0.1%
• Superimposed ripple:
≤0.6% peak-peak
(for τ
RC
= 0.3 ms)
≤0.25% rms
• Temperature coefficient:
±0.05%/K (idle)
• Armature-circuit time-constant (τ
A
):
≤4 µs
• Open-circuit voltage:
10...60 mV per rpm
• Torque:
1.5 Ncm
• Rotor moment of inertia:
GT 7.08:
0.4 kgcm
2
GT 7.16:
0.6 kgcm
2
• Permissible armature displacement:
±0.5 mm axial
±0.1 mm radial
• Vibration resistance:
100 m/s
2
≈ 10 g
EN 60068-2-6: 1996-05
(10-2000 Hz)
• Shock resistance:
1,000 m/s
2
≈ 100 g
EN 60068-2-27: 1995-03
(6 ms)
• Operating temperature:
-30°C...+130°C
• Isolation class:
B
• Protection class IEC 60529:
IP 55
• Climatic tests:
IEC 60068-2-3, Ca (dump heat, constant)
• Weight approx.:
GT 7.08:
110 g
GT 7.16:
160 g
• EMC according to:
EN 61000-6-2: 2006-03 (interference immunity)
EN 61000-6-4: 2007-09 (emitted interference)
10
Technical data