Salter Brecknell LP-470 Benutzerhandbuch

Seite 34

Advertising
background image

31

4.3 Printer Initialization
Printer initialization is used to clear DRAM and restore printer settings to defaults. The
only one exception is ribbon sensitivity, which will note be restored to default.

Printer initialization is activated by the following procedures.
1. Turn off the power switch.
2. Hold on the button then turn on the power switch.
3. Release the button when LED turns green after 5 amber blinks.

(Any green will do

during the 5 blinks).

The LED color will be changed as following:

Amber  red (5 blinks)  amber (5 blinks)  green (5 blinks)  green/amber
(5 blinks)  red/amber (5 blinks)  solid green


Printer configuration will be restore to defaults as below after initialization.

Parameter Default

setting

Speed

127 mm/sec (5 ips)

Density 8
Label Width

4” (101.6 mm)

Label Height

4” (101.6 mm)

Media Sensor Type Gap sensor
Gap Setting

0.12” (3.0 mm)

Print Direction

0

Reference Point

0,0 (upper left corner)

Offset 0
Tear Mode

On

Peel off Mode

Off

Cutter Mode

Off

Serial Port Settings 9600 bps, none parity, 8 data bits, 1 stop bit
Code Page

850

Country Code

001

Clear Flash Memory No
IP Address

DHCP

Note

Always do gap/black mark sensor calibration

after printer initialization.