TechniSat RV 600 E transfer socket Benutzerhandbuch

Seite 4

Advertising
background image

1)

Between two subscribers

Montage:

Mounting instructions:
- Only by qualified technicians
- Only indoor in dry places
- Mounting tools: stripping tool

Philips screwdriver size 1 or
standard screwdriver 5 x 0.8

- Do not damage the outer conductor when baring (screening factor cannot be attained)
- After the connection of the cable, make sure that no wires of the outer conductor touch the

interior conductor, otherwise a short-circuit may occur

- Do not touch the tips of the claws: Danger of injury!

The RV 600-10 E, RV 600-14 E, RV 600-17 E wall outlets may only be used for the follo-
wing systems:

- Loop through and star-wired distribution systems in single-cable systems with the

TechniRouter system

Attention: A short-circuit at the trunk while the receivers are both connected and turned on,

may damage or destroy the RV 600-10 E, RV 600-14 E, RV 600-17 E circuit

Connection

Frequency range/loss

(MHz/dB)

Through loss

(dB)

Decoupling

1)

(dB)

47-68

B I

87,5-108

FM

118-470

VHF

470-862

UHF

950-2150

Sat-ZF

TV

10/14/17

10/14/17 10/14/17

VHF: 1,0/0,7/0,7
UHF: 1,0/0,8/0,8
Sat-ZF:

1,9/1,5/1,5

VHF/UHF: > 42

IF: > 32

Radio

11/15/18

Sat-IF

10/14/17

TechniSat Digital GmbH, Postfach 560, 54541 Daun, www.technisat.de

ma_RV 600-xx-E_02082011.qxp 02.08.2011 14:06 Seite 4