TechniSat Line Amplifier 17Z Benutzerhandbuch
Seite 22

7 Technical data accessories to GigaSystem 17 / X, guaranteed
parameters
1) All other trunk lines have a signal
2) Related to broadband cable signal in BC grid (36 TV signals, 14 FM radio programmes), CTB (72 dB)
/ CSO (69 dB), with terrestrial reception individual channels are usually stronger, this is acceptable as
long as they remain <90 dBμV.
3) In accordance with EN 50083-3: IMA3 35 dB
22
GB
Terr:47.. 862MHz,
Sat: 0,95..2,15GHz
Intermediate
amplifier 17ZR
Active branch dis-
tributor 17/2AR
Passive distributor
17PR
Application
Amplification,
when the level is
reduced
spared branching of
two side trunks
signal splitting
Terr:47..862GHz,Sat: 0,95..2,15GHz
Terr.
Sat.
Terr.
Sat.
Terr.
Sat.
Trunk line gain
5...10dB,
adjustable
7...12dB
-1.2dB
-1...-1.5dB
Slope correction
fixed correction
none
Tap gain
5dB,
adjustable
3...6 dB
-4dB
-4dB
Slope correction
adjusta-
ble
fixed cor-
rection
none
Return loss
Trunks
Taps
10dB
14dB
8dB
10dB
Isolation
1)
Trunks
Taps
40dB
50dB, widely cascadable
45dB
45dB
Return path loss
Trunks
5 ... 30 MHz
Trunks
1.5dB
2dB
4.5dB
11dB
Input level
2)3)
recommeded
maximum
58 dBμV
55 dBμV
65 dBμV
70 dBμV
passive
75 dBμV
70 dBμV
75 dBμV
85 dBμV
Power supply
for unit
for LNB’s
via the trunk lines
from a 17/8G-power
supply
in the side trunks
not needed,
passive
from a unit with
power supply in the
main trunk
via one direct current
path
DC resistance of unit for one
voltage
< 50mOhm (one line has 130mOhm)
< 50mOhm
Power consumption from power supply
180mA (18V),
120mA (13V)
300mA (from 18V)
Screening level
in accordance with EN50083-2/A1 and TechniSelect S
Ambient conditions
-25...+55°C, overvoltage protection inputs, outputs < 5kV
Dimensions: L x W x H, Weight
212 x 58 x 45 mm; 0,7kg 212 x 105 x 45 mm; 1,3kg 212 x 69 x 45mm ; 0,9kg
Article number
0000/3269
0000/3270
0000/3268
GigaSystem_17_8_Zubehör_deu_engl_02032007.qxp 02.03.2007 11:27 Seite 22