PRESET

1. Preset mode

q The preset mode is available when

@5 PRESET button is pushed for more than 1 sec while DN-S3000 is

in Cue, pause or no disc mode.

w Turn the

#0 PARAMETERS knob to select the preset item.

e After selecting an item, push the

#0 PARAMETERS knob to select the preset data.

r To change other Preset items, repeat these steps.
t Push the

@5 PRESET, !0 CUE or i PLAY/PAUSE (

13

) button to exit from the Preset mode.

2. Preset items and data

The “*” mark next to the data indicates the default value.

(1)

AUTO CUE : Auto Cue level search on/off. (ON* / OFF)

(2) PITCH RANGE : Select the playing pitch range when the power is turned on.

(±4 / ±10* / ±16 / ±24%)

(3)

PLATTER : Select whether or not the Platter is to rotate during playback. (Turn round* / Turn stop)

(4)

PLATTER MODE MEMO :

When the Platter mode (DRAG-S and BRAKE) parameters, the source and the on/off setting are
stored, the stored data is set each time the power is turned on.
q To set the effect data, push the PARAMETERS knob and select “YES“.

• “Set OK?” flashes on the character display.

w Push the PARAMETERS knob again and select “OK” to execute setting the data.
e Once setting is completed, “Complete!” is displayed.

(5)

AUTO LOAD : Time for automatically loading disc. (OFF / 10 / 30 / 60* seconds)

(6)

EOM : Track end message start time. (OFF / 10* / 15 / 20 / 30 / 60 / 90 seconds)

(7)

FADER START MODE: Select 2-line type (Cue and Play) or 1 line type (Play and Pause).

(Play /Cue* / Play/Pause)

(8)

POWER ON PLAY : Playback starts when the power is turned on if a disc is loaded. (On / Off*)

(9)

SINGLE/CONTINUOUS/SINGLE PLAY LOCK :

Select the play mode when the power is turned on. (Single* / Continuous / S.PlayLock)

• When SINGLE PLAY LOCK is selected, track selection during playback is disabled. This

prevents playback from stopping when the Track Select Knob is turned accidentally during
playback. This mode is valid even when selected after turning the power on.

(10) ELAPSED/REMAIN: Select the time mode when the power is turned on.

(Elapsed* / Remain)

(11) MEMO ALL CLEAR : Clear all MEMO data in the non-volatile memory.

q To clear all MEMO data, push the PARAMETERS knob and select “YES”.

• “Clear OK?” flashes on the character display.

w Push the PARAMETERS knob again and select “OK” to execute clearing all MEMO data.

• “Memo Clear” is displayed on the character display while clearing.

e Once clearing is completed, “Complete!” is displayed.

(12) MEMO ALL COPY :

Copy all MEMO data from the master unit of DN-S3000 (or DN-S5000, DN-D9000, DN-2600F) to
the slave unit of DN-S3000 (or DN-S5000, DN-D9000) when both unit are connected by the normal
straight Cable. (See diagram for the cable.)
NOTE: Be sure CD player have no discs inside.

A straight cable used:

• Using the straight cable, connect the X-EFFECT terminals between two DN-S3000 units or

between one DN-2600F and one DN-S3000 unit or between one DN-D9000 and one DN-S3000
unit or between one DN-S5000 and one DN-S3000 unit.

• If a DN-2600F is the master unit, take the procedures below in the Preset mode of the DN-2600F

beforehand. (For details, refer to the DN-2600F’s operating instructions.)
✽ Set the “Copy Master” for the Preset item (14).

Then, step to the q below on the slave unit of DN-S3000.

• Copying can be performed using the DN-S3000 and DN-D9000 or the DN-S3000 and DN-S5000

in the same way as when using two units of the DN-S3000.

• Perform the copying operation as below on the slave unit of DN-S3000.

q To start copying, push the PARAMETERS knob and select “YES”. Now “Copy OK?”

messages flashes on the character display.

w Push the PARAMETERS knob again to confirm. Now “Start OK?” is displayed.

NOTE: If a DN-2600F is the master unit, take the procedures below in the Preset mode of

the DN-2600F here.
In the Preset item (15), first start copying on the DN-2600F. Then, step to e below
on the slave unit of DN-S3000.

e Push the PARAMETERS knob once again, and the unit starts copying when the MEMO data

are received from the master unit. Now “Copying” is displayed.
• If the master unit and the slave unit are not connected properly or the DN-2600F is not

prepared to start sending data, “Not Connect” is displayed on the character display.

r When copying is completed correctly, “Complete!” is displayed.

• “Copy Error” is displayed on the character display if copying was not completed correctly.
• “Not connect” is displayed on the charactor display if it is not possible to communicate

normally.

In this case, try the above procedure again.

• The copied MEMO data are added to the highest number area of the slave DN-S3000 unit.

(13) The DN-S3000’s software version is displayed. (SYSTEM / DSP / CD DRIVE)

(14) PRESET INITIALIZE : Set all the preset data back to the factory defaults.

q To clear the PRESET data, push the PARAMETERS knob.

“Initial OK?” flashes on the character display.

w Push the PARAMETERS knob again and select “OK” to start clear the preset data.

“Preset Int” is displayed on the character display while data clearing.

e Once clearing is completed, “Complete!” is displayed.

DN-S3000

DN-S5000 (X'EFFECT IN)

DN-2600F (X'EFFECT)

DN-D9000 (X'EFFECT)

X'EFFECT OUT

DN-S3000 (X'EFFECT IN)

X-EFFECT IN jack

DN-S3000-1

DN-S3000-2

X-EFFECT OUT jack

3.5 mm stereo mini cord

Advertising