Trouble- shooting, Warning – Desa BLP35ES Benutzerhandbuch

Seite 11

Advertising
background image

9

Never service heater while it is plugged in, connected to
propane supply, operating, or hot. Severe burns and
electrical shock can occur.

TROUBLE-

SHOOTING

Check current to electrical out-
let. If current is good, check
heater power cord for breaks.

Adjust motor/fan guard to keep
fan from hitting inside of
heater shell. Bend fan guard if
necessary.

Replace fan. See Fan, page 11.

Replace motor. See Motor,
page 10.

Repeat installation and opera-
tion instructions. See Installa-
tion,
page 5 and Operation,
page 6.

A) Check ignitor wire. Tighten
or reattach loose ignitor wire.
See Figure 13, page 12 for igni-
tor wire location.
B) Set gap between ignitor
electrode and target plate to 4.3
mm.
C) Tighten nut holding piezo
ignitor to base of heater.
D) Replace ignitor electrode.
See Ignitor, page 12.

This can happen when running
heater in temperatures above

29° C. Run heater in cooler

temperatures.

Check heater inlet and outlet.
Remove any obstructions.

Replace fan. See Fan, page 11.

!

WARNING

Use only in areas free of
high dust content.

Clean heater. See Mainte-
nance,
page 8.

No electrical power
to heater

Fan hitting inside of
heater shell

Fan blades bent

Defective motor

User did not follow instal-
lation or operation in-
structions properly

No spark at ignitor. To
test for spark, follow step
9 under Ignitor, page 12.
If you see spark at ignitor,
have heater serviced by
qualified service person.
If no spark seen:
A) Loose or disconnected
ignitor wire
B) Wrong spark gap
C) Piezo ignitor loose
D) Bad ignitor electrode

High surrounding air tem-
perature causing thermal
limit device to shut down
heater.

Restricted air flow

Damaged fan

Excessive dust or debris
in surrounding area

Fan does not turn
when heater is
plugged in.

Heater will not
ignite.

Heater shuts down
while running.

OBSERVED FAULT POSSIBLE CAUSE

REMEDY

!

WARNING