7

Warning Power Cord Table For PoE Power Supply (MSR 36-20):
The power cord set must be approved for the country where it is used.
WARNUNG Netzkabel Tabelle Für PoE Netzteil (MSR 36-20):
Das Netzkabel muss für das Land, in dem es verwendet wird, zugelassen werden.

警告:

PoE电源的电源线表格(MSR 36-20):

电源线组件必须满足使用的国家认证要求。

U.S.A. and
Canada

The cord set must be UL approved and CSA certified

The minimum specification for the flexible cord is:

No. 18 AWG

Type SV / SVT or SJ / SJT or SPT-2

3 conductor.

The cord set must have a rated current carrying capacity of at least 10A.

The attachment plug must be an earth-grounding type with a NEMA

5-15P (15A, 125V) or NEMA 6-15P (15A, 250V) configuration

United Kingdom

The supply plug must comply with BS1363 (3-pin, 13A) and be fitted with

a 13A fuse that complies with BS1362

The mains cord must <HAR> or <BASEC> marked and be of type

H03VVF3G1.0 (minimum).

Europe

The supply plug must comply with CEE 7/7 (“SCHUKO”)

The mains cord must <HAR> or <BASEC> marked and be of type

H05VVF3G0.75 (minimum)

Denmark

The supply plug must comply with section 107-2-D1, standard DK2-1a or

DK2-5a.

Switzerland

The supply plug must comply with SEV/ASE 1011

Der Netzstecker muss SEV/ASE 1011 entsprechen.

Argentina
(for 3 pins)

The power cord set must be certified by UL, IRAM, TÜV (or other

authorized certification body), for three conductors cables.

The attachment plug must be an earth-grounding type with an

IRAM-2073 (10 A, 250 V).

中国

电源线组件必须通过

CCC 认证。

使用符合

GB1002,额定值为 250V/10A 的单相两级带接地插头

电源线最小线径为

0.75mm

2

The appliance coupler (the connector to the unit and not the connector to the wall plug) must have a
configuration for mating with an EN 60320 / IEC 320 C13 appliance inlet.

Die Gerätesteckvorrichtung (der Anschluss an die Anlage, nicht an den Wandstecker) muss mit einer

Konfiguration nach EN 60320 / IEC 320 C13 versehen.