Taking the appliance into use – Aquapur ADR 1300 B2 Hand Steam Cleaner Benutzerhandbuch

Seite 10

Advertising
background image

8

ADR 1300 B2

GB

IE

To extend the optimal functioning of the appliance, mix the mains water with
distilled water as per the following table.

Water hardness

Ratios - distilled water to

mains water

very soft / soft

0

medium

1:1

hard

2:1

very hard

3:1

The water hardness level can be queried at your local water works.

Replace the lid on the water tank

4)

3.

Place the water tank

5)

3 slightly off set below the appliance, so that the mark-

ing on the water tank points to the open lock

on the appliance.

Turn the water tank

6)

3 so far that the marking points to the closed lock

.

Thereby, ensure that the hose that sucks the water up is always lying in the
front area of the water tank 3. If you do not, it may happen that during use
some water will remain in the water tank 3.

Taking the appliance into use

Insert the plug into a mains power socket. The red control lamp

1)

7 glows.

As soon as the appliance is ready for use the green control lamp

2)

8 starts to

glow - the red control lamp 7 continues to glow.

NOTICE

During the heating up period it can happen that there is an occasional

escape of steam from the steam nozzle q.

Press the steam lever

3)

1 downwards. The pump pumps water into the heater

element, steam is generated and exits from the steam nozzle q. Should the
steam blast subside, continue to hold the steam lever 1 down. More water
is pumped in and after a short time the steam vapour level increases.