not carry out conversion work on the

equipment.

• Please read the notes in the operating

instructions on the topic of “mainte-

nance and cleaning”. Any measures

above and beyond these, particularly

opening the equipment, are to be car-

ried out by an electrician. In the case

of repairs, always contact our service

centre.

Electrical safety:

Caution: to avoid accidents and in-

juries from electric shocks:

• After erection, the mains plug must be

freely accessible when the equipment

is in operation.

• Before operating your new pump, have

a specialist check:

-

The earthing, the protective multiple

earthing; the residual current circuit

breaking must be compliant with the

safety regulations of the energy sup-

ply company and function without

fault,

-

The protection of the electrical plug

connections from the wet.

-

If there is a risk of flooding, fix the

plug connections in an area that is

safe from flooding.

• Ensure that the mains voltage match-

es the specifications on the rating

plate.

• The electrical installation shall be ac-

cording to national wiring rules.

• Connect the equipment only to a

socket with a residual current protec-

tion device (residual current circuit

breaker) with a rated current of not

more than 30 mA; minimum fuse 6

amperes.

• Before each use, check the equip-

ment, cable and plug for damage. De-

fective cables are not to be repaired,

but rather replaced by new ones.

Have any damage to your equipment

repaired by a specialist.

• If the power cable for this equipment

is damaged, it must be replaced by

the manufacturer, a customer ser-

vice agent of the same or a similarly

qualified person in order to prevent

hazards.

• Do not pull the plug from the socket

by the cable. Protect the cable from

heat, oil and sharp edges.

• Do not carry or fix the equipment by

the cable.

• Use only extension cables that are

protected from spray water and de-

signed for outdoor use. Always fully

unroll a cable drum before use. Check

the cable for damage.

• Before any work on the equipment,

during work breaks and in the case

of non-use, remove the plug from the

socket.

• The cross-section of mains connec-

tion lines must be no smaller than

rubber hose lines with the designation

H07RN-F. The line must be 10 m long.

Areas of Application

The foul water submersible pump is a

drainage pump and designed for trans-

porting water and sewage water (max.

particle size 35 mm) up to a temperature

of max. 35°C.

It may be used e.g. domestically, in horti-

culture, in agriculture and in the sanitary

industry. It is suitable e.g. for pumping

around and pumping out tanks and con-

tainers, for pumping out flooded cellars

and for removing water from fountains

and drains.