Troubleshooting guide – Florabest FGPA 1000 A1 Benutzerhandbuch

Seite 11

Advertising
background image

GB/IE

- 11 -

18. Troubleshooting guide

Motor not running

Cause

Remedy

- Power supply not connected
- Impeller blocked, thermostat has switched off

- Check voltage supply
- Take pump apart and clean it

Pump not priming

Cause

Remedy

- Intake valve not in the water
- No water in the pump chamber
- Air in the intake line
- Intake valve leaking
- Intake cage (intake valve) blocked
- Max. intake height exceeded

- Place intake valve in water
- Fill pump housing with water
- Check sealing of intake line
- Clean intake valve
- Clean intake cage
- Check intake height

Insuffi cient pumping rate

Cause

Remedy

- Intake height too high
- Intake cage soiled
- Water level falling rapidly
- Pump performance reduced by foreign bodies

(sand, stones, etc.)

- Check intake height
- Clean intake cage
- Place intake valve lower down
- Clean pump and replace wearing parts

Thermostat switches off the pump

Cause

Remedy

- Motor overloaded, excessive friction caused

by foreign bodies

- Dismantle and clean pump, prevent intake of

foreign bodies (fi lter)

Caution! The pump must not run dry.

Anleitung_4180302.indb 11

Anleitung_4180302.indb 11

18.09.12 10:20

18.09.12 10:20

Advertising
Dieses Handbuch ist für die folgenden Produkte bezogen werden: