4.4 TRIAMP

®

MK II AND MIDI

With the MSM-1 MIDI Module

installed, you can use your

multieffects processor to sel-

ect TriAmp

®

MK II channels

and turn the FX LOOP on or

off via MIDI.

Installing the MSM-1 MIDI Module

NOTE (VERY IMPORTANT):

The following instructions are intended solely for

a factory authorized technician.

• Unplug the amp's mains cord from the wall

socket and remove all connected cables

(e.g. to the spring reverb or speakers).

• Remove the amp's rear panel cover so you can

access the tubes.

• Prepare a suitable spot to set the amp chassis

(for instance two books placed the same

distance apart as the two transformers),

or remove the power amp tubes.

• Remove the four retaining screws that hold the

chassis in place, and carefully pull the amp

chassis out of the wood housing.

• Remove the MIDI Module port cover plate from

the rear panel of the chassis.

• Insert the included flat cable connector plug in

the MSM-1's socket so that the color-coded wire

faces the notch on the socket.

MSM-1 socket and indicator notch.

• Insert the MSM-1 into the module port, and affix

it in place using the same four screws you just

removed a moment ago. Make sure the writing

on the MSM-1 reads in the same direction as

that on the rest of the chassis back.

Location of the sockets.

• On the control circuit board you will find the

socket for the connector on the other end of

the ribbon cable. Also insert this connector in

the socket so that the color-coded wire faces

the notch on the socket.

• Double-check that the module and the

connectors are seated correctly.

• Replace the chassis in the housing and, if you

removed the tubes, the tubes in the chassis.

• Replace the amp's rear panel, and reconnect

the cables to the reverb and speakers.

• To use the MIDI LEARN function with the

TriAmp

®

MK II, please refer to the instructions

included with the MSM-1 MIDI Module.

The moment power is applied to the amp,

the MIDI functions of the TriAmp

®

MK II are

immediately available. Please check all

switching functions of the amp.