1. Pull off the fountain socket

1

and nozzle tube

2

.

2. Unscrew the fountain insert

B

and clean it.

3. Remove the filter housing

4

from the motor housing

6

, and

clean it.

4. Turn the pump inlet

5

anticlockwise and pull it vertically off

the motor housing

6

(bayonet socket).

5. Take the impeller

A

out of the motor housing

6

and clean it.

6. Push the cleaned impeller

A

back into the motor housing

6

.

7. Push the pump inlet

5

vertically onto the motor housing

6

and tighten it clockwise. (If the pump is to suck from
underneath, the thread must face downwards).

8. Push the filter housing

4

back on to the motor housing

6

.

9. Screw the desired fountain insert

B

into the fountain

socket

1

.

10. Plug the fountain socket

1

and nozzle tube

2

back into

place.

Cleaning the RP 600 :