Tlm 49 – Neumann.Berlin TLM 49 Benutzerhandbuch

Seite 3

Advertising
background image

4

5

TLM 49

Technische Daten

Akustische Arbeitsweise ........... Druckgradienten-

empfänger

Richtcharakteristik ..................................... Niere

Übertragungsbereich .................... 20 Hz...20 kHz

Feldübertra-
gungsfaktor

1)

.......... 13 mV/Pa = –38 dBV ± 1 dB

Nennimpedanz ....................................... 50 Ohm

Nennlastimpedanz .............................. 1000 Ohm

Geräuschpegelabstand

2)

,

CCIR

3)

....................................................... 71 dB

Geräuschpegelabstand

2)

,

A-bewertet

3)

............................................. 82 dB

Ersatzgeräuschpegel,
CCIR

3)

....................................................... 23 dB

Ersatzgeräuschpegel,
A-bewertet

3)

......................................... 12 dB-A

Grenzschalldruckpegel für

4)

k < 0,5 % Klirrfaktor ............................... 110 dB
k < 5 % Klirrfaktor .................................. 129 dB

Max. Ausgangsspannung für k < 5% .......... –1 dBu

Speisespannung

5)

.............................. 48 V ± 4 V

Stromaufnahme

5)

..................................... 3,2 mA

Gewicht ................................................... 825 g

Durchmesser ............................................ 78 mm

Länge ................................................... 165 mm

94 dB SPL 1 Pa = 10µbar
0dB 20µPa

1)

bei 1 kHz an 1 kOhm Nennlastimpedanz.

2)

bezogen auf 94 dB SPL

3)

nach IEC 60268-1;
CCIR-Bewertung nach CCIR 468-3, Quasi-Spitzenwert;
A-Bewertung nach IEC 61672-1, Effektivwert

4)

Klirrfaktor des Mikrophonverstärkers bei einer Eingangs-
spannung, die der von der Kapsel beim entsprechenden
Schalldruck abgegebenen Spannung entspricht.

5)

Phantomspeisung (P48, IEC 61938).

Technical Specifications

Acoustical op. principle ............. Pressure gradient

transducer

Polar pattern .......................................... cardioid

Frequency response ..................... 20 Hz...20 kHz

Sensitivity

1) ...............

13 mV/Pa = –38 dBV ± 1 dB

Nominal impedance ............................... 50 ohms

Nominal load impedance .................... 1000 ohms

Signal-to-noise ratio

2)

,

CCIR

3)

....................................................... 71 dB

Signal-to-noise ratio

2)

,

A-weighted

3)

............................................. 82 dB

Equivalent noise level,
CCIR

3)

....................................................... 23 dB

Equivalent noise level,
A-weighted

3)

.......................................... 12 dB-A

Max. SPL for

4)

less than 0.5 % THD ................................ 110 dB
less than 5 % THD ................................... 129 dB

Max. output voltage for THD < 5% ............. –1 dBu

Supply voltage

5) .........................................

48 V ± 4 V

Current consumption

5) .....................................

3.2 mA

Weight ...................................................... 825 g

Diameter .................................................. 78 mm

Length .................................................. 165 mm

94 dB SPL 1 Pa = 10µbar
0dB 20µPa

1)

at 1 kHz into 1 kohms rated load impedance.

2)

re 94 dB SPL

3)

according to IEC 60268-1;
CCIR-weighting acccording to CCIR 468-3, quasi peak;
A-weighting according to IEC 61672-1, RMS

4)

THD of microphone amplifier at an input voltage equivalent
to the capsule output at the specified SPL.

5)

Phantom powering (P48, IEC 61938).

gemessen im freien Schallfeld nach IEC 60268-4
measured in free-field conditions (IEC 60268-4)

Frequenzgänge und Polardiagramm