Instructions for the Installer

The instructions given below are designed

specifically for a qualified installer and

should aid him or her to perform all

installation, adjustment, and maintenance

operations with absolute precision and in

compliance with all current legislation and

regulations. We strongly recommend that all

operations for the installation of your cooker

be carryed out by Qualified Personnel in

accordance with existing rules and

regulations.

Electrical connection

Prior to making the electrical connection, make sure that:

— the protection fuse and the domestic wiring

system are suitable to carry the total electric load of the

oven (see rating plate);

— your domestic wiring system has an efficient

earth connection in compliance with rules and laws in

force;

— the wall socket or the omnipole switch used for

the electrical connection can easily be reached after the

oven is built in.

This appliance is delivered without an electric supply cable,

therefore, you will have to fit to it a supply cable with standard

plug, suitable for the total electric load shown on the rating plate.

The plug is to be inserted into a suitable wall socket. If you require

a direct connection to the electric network (mains), it will be

necessary to fit between the appliance and the mains an

omnipole switch, with a minimum gap between contacts of 3

mm, suitable for the required load and in compliance with rules in

force. The green & yellow ground wire must not be interrupted by

the switch, and should be 2-3 cm longer than the phase and

neutral wires. The supply cable must in all cases be laid out in

such a way as to ensure that it does not reach at any given

point a temperature 50°C higher than the ambient temperature.

Suitable power supply cables are the following types,

considering the respective necessary section of cable: H07 RN-

F, H05 RN-F, H05 RR-F, H05 VV-F, H05 V2V2-F (T90), H05

BB-F.

Connecting the terminal board

The appliance incorporates an easily accessible 6-pole terminal

board whose jumpers (bridges) are already pre-set for operation

on 400 V tri-phase with neutral wire (Fig. 9). In case a different

mains voltage is present, the jumpers on the terminal board must

be rearranged as shown in the diagram (Fig. 10). The ground
cable must be connected to terminal

. After connecting the

supply cable to the terminal board, secure it with a junction clamp.

Electrical connection with the hob

This oven can be connected to hobs indicated in the

paragraph "Technical data". The socket for connecting the

hob is located at the top of the oven cabinet. The hobs

come complete with connecting leads for the hot plates/

heat areas and ground cable; these leads feature plug-in

connectors. Connection of the hob to the oven is carried

out by plugging-in these connectors to the corresponding

oven socket.

The plug-to-socket connection design is such as to prevent

possible wrong plugging-ins.
The Manufacturer disclaims any liability in case

these accident-preventing rules are not observed.

230V 3~

1 2 3 4 5

L1 L2 L3 PE

230V 1~

1 2 3 4 5

L1 N PE

400V 2N~

1 2 3 4 5

L1 L2 N PE

400V 3N~

1 2 3 4 5

L1 L2 L3 N PE

Ø 4x2,5mm²

Ø 3x2,5mm²

Ø 4x2,5mm²

Ø 5x1,5mm²

Fig. 9

Fig. 10