Deviation in characteristics and characteristics

4)

Average temperature coeffi-

cient of the zero signal

(temperature error)

0.06 %/10 K

Resolution, general

max. 1 mm

Ultrasonic frequency

70 kHz

Interval

>2 s (dependent on the parameter adjustment)

Beam angle at -3 dB

11°

Adjustment time

5)

>3 s (dependent on the parameter adjustment)

Accuracy

better than 0.2 % or ±4 mm (see diagram)

5 m

4 m

3 m

2 m

1 m

10 mm

4 mm

-4 mm

-10 mm

Fig. 29: Accuracy VEGASON S 62

Ambient conditions

Ambient, storage and trans-

port temperature

-40 … +80 °C

Process conditions

Vessel pressure

-0,2 … 2 bar/-20 … 200 kPa

Process temperature (trans-

ducer temperature)

-40 … +80 °C

Vibration resistance

mechanical vibrations with 4 g and 5 … 100 Hz

6)

Electromechanical data

Cable entry

1x cable entry M20x1.5 (cable-ø 5 … 9 mm), 1x blind stopper M20x1.5

Spring-loaded terminals

for wire cross-sections up to 2.5 mm²

Indicating and adjustment module

Power supply and data

transmission

through the sensor via sliding contacts

4)

Relating to the nominal range, incl. hysteresis and repeatability, determined according to the limit point method.

5)

Time to output the correct level (with max. 10 % deviation) after a sudden level change.

6)

Tested according to the regulations of German Lloyd, GL directive 2