Application areas and function

This family of miniature controllers, in combination with
proportional valves, serves to control
• Liquid flow in piping

(Flow rate controller 8623-2)

• Pressure in liquids and

(Pressure controller 8624-2)

flowing gases

• Mixing temperature of

(Temperature controller 8625-2)

two media

• Suitable for proportional valves

types 6022, 6023, 6223, 2832, 2834

• Controller with adjustable PI control behaviour
• Direct installation on the valve, thanks to compact design of

device

• Direct actuation of a proportional valve
• Setpoint specification via standard signal 4-20 mA / 0-10 V
• Scaling

• Measurement of flow rate by means of a flow rate sensor with

frequency output (frequency proportional to flow rate)

• For flow rate sensors with frequency output of max. 1000 Hz

• Proportional control

• Measurement of the pressure by means of a pressure

transmitter with standard output signal

• Measurement of the temperature by means of a PT 100 sensor

• Heating / cooling

8623-2

8624-2

8625-2

Safety notes

ATTENTION!

• Observe the general technical regulations when planning

application and operation of the unit!

• Take precautions to avoid inadvertent actuation or

unwanted interference!

• Pipelines and valves under pressure must not be

disconnected!

• Always isolate the voltage supply before working on the

system!

• If this instruction is not followed, or if any inadmissible

tampering with the appliance takes place, we will accept no
further liability, and the guarantee on the appliance and its
accessories will become invalid!

ATTENTION

EXERCISE CAUTION ON HANDLING!

ELECTROSTATICALLY SENSITIVE

COMPONENTS / MODULES

This device contains electronic components that are sensitive to
electrostatic discharge (ESD). Contact to electrostatically
charged persons or objects will endanger these components. In
the worst case, they will be immediately destroyed or will fail after
commissioning. Observe the requirements of EN 100 015 - 1 in
order to minimize the possibility of, or avoid, damage from
instantaneous electrostatic discharge. Also take care not to touch
components that are under supply voltage.

NIEDERLASSUNGEN / BRANCH OFFICES

Operating Instructions 0507/03_EU-ML_00804584

To ensure the devices function correctly, and have along
service life, please comply with the information in these

Operating Instructions, as well as the Applications Conditions and
the permissible values specified in the data sheets for the propor-
tional valves used, and the types 8623-2, 8624-2 or 8625-2
controller.

The quickstart foldout is a supplement to the Operating
Instructions. More detailed information is to be found on the
enclosed CD.

GENERAL NOTES

FUNCTION

TECHN

We reserve the right to make technical changes without notice.

Contact addresses / Kontaktadressen

Germany / Deutschland / Allemange

Bürkert Fluid Control System

Sales Centre

Chr.-Bürkert-Str. 13-17

D-74653 Ingelfingen

Tel. + 49 (0) 7940 - 10 91 111

Fax + 49 (0) 7940 - 10 91 448

E-mail:

[email protected]

International

Contact addresses can be found on the internet at:

Die Kontaktadressen finden Sie im Internet unter:

Les adresses se trouvent sur internet sous :

www.burkert.com Bürkert / Company / Locations

Advertising
Dieses Handbuch ist für die folgenden Produkte bezogen werden: