IMPAC pyrometers ISQ 5 · ISQ 5-LO

5

Legend

Note: The note symbol indicates tips and useful information in this manual.
All notes should be read with regard to an effective operation of the instrument.

Security note laser beam
Indicates to the danger of a built-in laser targeting light.

MB

Shortcut for Temperature range (in German: Messbereich)


Terminology

The used terminology corresponds to the VDI- / VDE-directives 3511, page 4.


Disposal / decommissioning

Inoperable IMPAC pyrometers have to be disposed corresponding to the local regulations of electro or elec-
tronic material.


1

Technical data


Temperature ranges:

ISQ 5

600 to 1400°C (MB 14)

ISQ 5-LO 700 to 1800°C (MB 18)

700 to 1800°C (MB 18)

800 to 2500°C (MB 25)

800 to 2500°C (MB 25)

1000 to 3000°C (MB 30)

Sub range:

any range adjustable within the temperature range, minimum span 51°C

Spectral ranges:

channel 1: 0.9 µm; channel 2: 1.05 µm

Power supply:

24 V DC ± 25%, stabilised, ripple < 50 mV

Power consumption:

 3 W (incl. active laser targeting light)

Analog output:

0 to 20 mA or 4 to 20 mA, switchable, linear in temperature, load independent DC

Interface:

optional RS232 or RS485 (addressable), half duplex, baud rate 1.2 up to 38.4 kBd

Resolution:

0.1°C at the interface
at the analog output < 0.1% of the adjusted temperature range but min. 0.1°C

Isolation:

power supply, output (digital and analog) are galvanically isolated against each other

Parameters:

adjustable on the converter’s rear side:

emissivity slope, response time, analog output 0 to 20 mA or 4 to 20 mA,
online / offline mode

additionally via interface adjustable and readable:

2-color / 1-color temperature signal, according to this emissivity slope or emissiv-
ity, temperature sub range, settings for maximum value storage, address, baud
rate, switch off limit, warning level lens contamination monitoring system.

via interface readable only:

measured value, internal temperature of the unit

Maximum value
storage:

single or double storage, clear modes: time (off; 0.01 s; 0.05 s; 0.25 s; 1 s; 5 s;
25 s), external clear contact, via interface or automatic “hot object mode“, hold
function for freezing the current temperature reading (not for ISQ 5-C)

Emissivity slope K:

(

1

/

2

): 0.800 to 1.250

Emissivity

0.05 to 1.00 (in 1-color mode)

Response time: t

90

:

< 10 ms, adjustable to 0.01 s; 0.05 s; 0.25 s; 1 s; 3 s; 10 s

Switch off limit:

adjustable via interface: 2% to 50%

Contamination
warning:

Relay contact, max. continuous current 0.4 A,
setting of the switch level: 0 (off) ... 99%

Accuracy

(T

amb

=25°C, K=1, t

90

=1 s)

< 1500°C: 0.5% of reading in °C + 2°C
> 1500°C: 1% of reading in °C

Repeatability:

0.2% of reading in °C + 2°C

Noise equivalent
temperature difference
(NETD):
(K=1, t

90

=10 ms,

T

amb.

=10...40°C)

MB 14: 1°C

(at 610°C measuring temperature)

0.1°C (at 800°C measuring temperature)

MB 18: 0.4°C (at 710°C measuring temperature)

0.1°C (at 800°C measuring temperature)

MB 25: 0.4°C (at 810°C measuring temperature)