Options / model variants

NEPTUNE 5 SB FA

8.2

Indication lights on control panel

8.3 Other

Faults

Indication light

Cause

Remedy

fl ashing

>

see FLO

see FLO

ON

>

Low fuel level

Fill fuel tank
Cold water operation possible

>

Low Nilfi sk-ALTO AntiStone
(Anti-Scale) level

Fill Nilfi sk-ALTO AntiStone (Anti-
Scale) tank

fl ashing

>

Service interval: Service due
in 20 hours

Contact Nilfi sk-ALTO Service

ON

>

Service interval expired

Contact Nilfi sk-ALTO Service

ON

>

Pump oil low

Fill to proper level

Fault

Cause

Remedy

not ON

>

Power cord not properly
connected to power supply

Check power cord connetction

Check fuse (see chapter 9.4 Technical
Data)

Pressure too low

>

High pressure nozzle worn
out

Replace nozzle

>

Pressure regulation set to low
pressure

Turn the twist grip on safety control
block clockwise (+)

Machine is running with
pulsating pressure and
makes knocking noise

>

Pump has drawn in air due to
detergent tank being empty

Close detergent valve. Remove lance
from gun. Operate spray gun and let
machine run until air in pump is gone
and the machine is running normally/
calm again.

No detergents drawn in

>

Detergent tank empty

Fill detergent tank

>

Dirt in detergent tank

Clean detergent tank

>

Suction valve at cleaning
agent inlet soiled

Remove suction valve and clean or
replace

Burner soots

>

fuel contamination

Contact Nilfi sk-ALTO Service

>

Burner sooted or adjustment
incorrect