ROTHENBERGER ROWELD P 125 115V Benutzerhandbuch

Seite 16

Advertising
background image

14

ENGLISH

Table 2: Guide value table for PE-HD pursuant to DVS 2207 T1 (09/2005):

Pipe outer Heating timeHeating time Positioning

Cooling time

holding total

(sec) (min)

diameter SDR

6 – 7,4 - 11

SDR

17

(mm) (sec)

(sec)

(sec)

16 5

4

6

2

20

5

4

6

2

25 7

4

10

2

32

8

6

10

4

40 12

6

20

4

50

18

6

20

4

63 24

8

30

6

75

30

18

8

30

6

90 40

26

8

40

6

110

50

36

10

50

8

125 60

46

10

60

8

Table 3: Guide value table for PP pursuant to DVS 2207 T11 (08/2008):

Pipe outer Heating timeHeating time Positioning

Cooling time

holding total

(sec) (min)

diameter SDR

6 – 7,4 - 11

SDR

17 – 17,6

(mm) (sec)

(sec)

(sec)

16 5

4

6

2

20

5

4

6

2

25 7

4

10

2

32

8

6

10

4

40 12

6

20

4

50

18

6

20

4

63 24

10

8

30

6

75

30

15

8

30

6

90 40

22

8

40

6

110

50

30

10

50

8

125 60

35

10

60

8

Table 4: Guide value table for PVDF pursuant to DVS 2207 T15 (12/2005):

Pipe outer

min. pipe Heating time Positioning

Cooling time

holding total

(sec) (min)

diameter wall

thickn.

(mm) (mm)

(sec)

(sec)

16 1,5

4

4

6

2

20

1,9

6

4

6

2

25 1,9

8

4

6

2

32

2,4

10

4

12

4

40 2,4

12

4

12

4

50

3,0

18

4

12

4

63 3,0

20

6

18

6

75

3,0

22

6

18

6

90 3,0

25

6

18

6

110

3,0

30

6

24

8

Advertising