Festo Распределители для пневмоостровов по ISO 5599-2 Benutzerhandbuch

Seite 4

Advertising
background image

3. Press the sealing gasket back into

3.

die Dichtungsplatte wieder

auf.

valve

Possible additional

intermediate plate

weitere

Zwischenplatte

1. Screw the locating spigots provided into

the sub-base.

The square base of the threaded spigots

must be aligned parallel to the longitudinal

axial of the sub-base. In order to do this, it

may be necessary for the threaded bolts to

be turned back by a

turn.

2. Plug the solenoid plate MUH on to the
threaded spigots in the sub-base.
When installed, the spigots remain re-

cessed within the body of the MUH.

3. Place the

valve or additional interme-

diate plate (restrictor plate, pressure regula-

tor) on to the

The attachment screws are then screwed

into the threaded spigots located within the
solenoid plate.

electrical

3 Supply voltage coil A

2 4 Supply voltage coil
5

Ground

Sub-base

1. Drehen Sie die mitgelieferten Gewinde-

bolzen in die

ein.

Die Vierkantsockel der Gewindebolzen

parallel zur Langsachse der

ausgerichtet sein. Dazu sind

die Gewindebolzen ggf. bis zu einer

drehung

2. Stecken Sie die MUH auf die Gewinde-
bolzen in der
Die Gewindebolzen bleiben in der
steckten MUH versenkt.

3. Plazieren Sie das

oder weitere

Zwischenplatten (Drosselplatte,

lerplatte) auf der MUH.
Die Befestigungsschrauben des

ten Bauteils werden in die versenkten

windebolzen der MUH

elektrisch

Pin assignment Pinbelegung

Lateral view of MUH

MUH-seitig

1

3 Versorgungsspannung Spule A

2

4 Versorgungsspannung Spule B

5

Erde

Advertising