WIKA CTH6200 Benutzerhandbuch

Seite 16

Advertising
background image

WIKA Betriebsanleitung Hand-Held Thermometer

2146872 09/2004 GB/D

16

GB

WIKA Operating Instructions Hand-Held Thermometer

Hand-Held Thermometer
CTH 6200

If logger memory contains recordings already:
When key:

´Store/Quit´ is pressed for 2 seconds, the choice for

clearing the logger memory will be displayed:

clear

clear nothing

all recordings

(cancel menu)

clear the last

recording

The selection can be made by key:

´Min´ and key: ´Max´. Key:

´Store/Quit´ enters the choice.

If the logger memory is full, the display will show:

Viewing Recorded Measurings
Within the "LoGG Stor" function the measurings can be viewed

directly in the display not only by means of a computer (like at

"Func CYCL"): press 2 seconds

´Set/Menu´. The first menu

displayed now is "rEAd LoGG" (read logger data). After pressing

key:

´Tara´ the measurement recorded last will be displayed,

changing between the different values referring to the measure-

ment also is done by pressing key: ´

Tara´.

Changing the measurement is done by pressing the key:

´Min´ or

key:

´Max´.

3.2 Func-CYCL": Automatic recording with selectable cycle-time

The Logger-Cycle-Time is setable (p.r.t. Configuration). For

example "CYCL" = 60: A measuring is recorded after each 60
seconds.

Max. number of measurings: 16384
Cycle time:

0:01 ... 30:00 (minutes: seconds, min 1 s,
max 1 h), selectable in the configuration

A measuring contains:

Current measuring value at time of recording