Cleaning the Air filter (continued)

3

Clean the air filter with a vacuum cleaner

4

Install the air filter

When the air filter becomes clogged with dust, etc., the projector power may turn off to
prevent the internal heat level from rising. (The lamp indicator color changes to red.)
Do not operate the projector with the air filter removed. (If used with the air filter removed,
dust can enter the LCD panel and produce an adverse effect on image quality.)

Caution

Lamp

Message table

Even when the lamp is at a high temperature, the power to the projector may cut off to prevent
an excessive temperature increase inside the projector. (The POWER indicator turns off.) Turn
off the MAIN POWER switch, wait for some 20 minutes and turn on the MAIN POWER
switch again. If the projector is not recovered after turning on the MAIN POWER switch,
please contact BOXLIGHT.

Caution

The light source lamp has a service life.
When used for an extended time, the images may become darker and the colors may deteriorate.
A malfunction could occur if the projector is used in this condition, so replace the lamp with a new one.
The indicator or message appears when the power is turned on will indicate that the lamp should be replaced.
At such time, it is necessary to replace the lamp with a new one. For lamp replacement, please contact
BOXLIGHT.

The following messages are displayed on the screen.

*1 This display will disappear after 3min. but will reappear when the power is turned on again.

Screen displays

CHANGE THE LAMP“CALL

A MAINTENANCE PERSON”

“CHANGE THE LAMP”

“CALL

A MAINTENANCE PERSON”

“THE POWER WILL

TURN OFF AFTER

*

hr.”

Blinking of

“CHANGE THE LAMP”

NO INPUT IS DETECTED

SYNC IS OUT OF RANGE

The total lamp usage time is nearing the service life of the lamp. Replace with a new lamp.

The lamp will turn off automatically when the lamp replacement time has been exceeded.

*

1

The total lamp time is nearing the lamp replacement time. After (*) hours, the lamp will turn

off. Quickly replace with a new lamp.

*

1

*

Indicates the number of hours until the lamp turns off automatically.

The total lamp time has exceeded the replacement time. The indicator will blink for

approximately 10 min. and then turn off automatically. Replace with a new lamp.

There is no signal input (refer to pages 22, 23).

The current horizontal or vertical frequency cannot be used by this projector (refer to pages 23, 24).