Electrical installation

Connecting the supply voltage

Mains connection (X101)

5

l

87

LDCDS−ELx7xx DE/EN 4.0

5.2

Connecting the supply voltage

5.2.1

Mains connection (X101)

(

Stop!

No device protection against excessive input voltage
The voltage input is not fused internally.
Possible consequences:

ƒ

The device can be destroyed when the input voltage is too high.

Protective measures:

ƒ

Observe the max. permissible input voltage.

ƒ

Professionally fuse the device on the input side against voltage fluctuations
and voltage peaks.

)

Note!

The IPC boots up as soon as the supply voltage is applied.
After the operating system has been shut down, the IPC switches off
automatically. For restarting, the supply voltage has to be disconnected for a
short time.

L1

N

PE

L1 N

+

0V

+24

+

~

=

0 V PE +24 V

+

0

1

F

S

Elx7xx−006

0 Panel PC

1 Power supply unit

Description

Connection type

Cable type

0V

U

24 V DC supply connection

3−pole Phoenix Combicon

socket

Cable (max. conductor

cross−section: 2.5 mm

2

) with

Phoenix Combicon plug,

MSTB 2.5 / 3−STF−5.08

IPC001

PE connection

M4 threaded bolt

Separate earthing conductor

(min. 2.5 mm

2

) with ring

cable lug

IPC001

Advertising