2 controls and displays, Controls and displays, Operation – Lenze EL 9700 Benutzerhandbuch

Seite 92

Advertising
background image

Operation

Controls and displays
Panel PC EL 870 / EL 1700 / EL 1700s / EL 2700 / EL 5700 / EL 9700

6

l

92

LDCDS−ELx7xx DE/EN 4.0

6.2

Controls and displays

6.2.1

Panel PC EL 870 / EL 1700 / EL 1700s / EL 2700 / EL 5700 / EL 9700

-

F3

Fail

Power

F1

+

F2

Status

1
2

0

3

4

ELx7xx007

Pos. Designation

Function

Standard mode

Service mode

Switch on mode:

Press "

[" for 5 s

Switch off mode:

Press "

[" or wait for 35 s

0 Display

Application−dependent

1 Status LEDs

Power (green):

l

Is ON when the supply voltage is present.

Fail (red):

l

Is On when a power supply failure has occurred.

l

Is blinking when the screen signal is missing.

Status (yellow):

l

Indicates access to a storage medium.

2 Function keys

F1 ... F3: Send key code for Shift−Fx

Tool: Application−dependent
+: Increase screen brightness
−: Reduce screen brightness

3 Reset button

Reset PC (restart)

4 Status LEDs

Error (red):

l

Is lit if a power supply failure has occurred.

l

Is blinking when the screen signal is missing.

HD (yellow):

l

Indicates access to a storage medium.

Power (green):

l

Is lit when the supply voltage is present.

l

Flashes (

−−−

−−−

) in the case of a hardware error.

l

Is blinking (

−−

−−

) when the ACU UPS (optional) is being charged.

l

Is blinking (

−−

−−

−−

−−

) when there is a supply voltage failure and the device is being

supplied by the ACU UPS.

l

Is blinking (

) when the supply voltage of the ACU UPS is too low (e.g.

rechargeable battery is empty or missing).

l

Blinks 4 x per second if the ACCU−PACK causes a short circuit or if the CAPS−PACK
is completely discharged.

Advertising
Dieses Handbuch ist für die folgenden Produkte bezogen werden: