Electrical data, Technical data – Lenze EPCZEBED Benutzerhandbuch

Seite 47

Advertising
background image

Technical data

Electrical data

4

l

47

BA_DVIUSB DE/EN 5.0

Operating conditions

Mounting conditions

Mounting place

DVI/USB TX4

In the control cabinet, near the IPC
IPC <−> DVI/USB TX4 cable length:

l

Standard cable (scope of supply): max. 2 m

l

Lenze DVI/USB cable set: 5 m

DVI/USB RX4

MP system: to the back of the device
CS system: into the mounting frame of the device
DVI/USB TX4 <−> RX4 cable length: 10 ... 35 m

Ambient conditions

Climatic

Storage

−25 ... +70 °C

Transport

−25 ... +70 °C

Operation

0 ... +50 °C

Relative humidity

10 ... 95 %, non−condensing

Site altitude

< 3000 m amsl

4.2

Electrical data

Rated data

Operating voltage

+24 V DC (18 ... 30 V)
With MP 9000 DVI/CS 9000 DVI and a transmission
path > 20 m:
+24 V DC (20 ... 30 V)

Input current DVI/USB TX

without optional supply of the display
unit

max. 0.2 A (standby < 50 mA)

with optional supply of the display unit

max. 2 A

Output current DVI/USB RX
(optional 24V supply of the display unit)

max. 1.8 A

Transmittable graphics resolution

VGA (640 x 480 pixels) to SXGA (1280 x 1024 pixels)

USB connection

USB 1.1 and 2.0, max. 12 Mbit/s (full speed)