Electrical installation

Important notes

6

l

53

BA_DVIUSB DE/EN 5.0

(

Stop!

No device protection against excessive input voltage

The voltage input is not fused internally.
Possible consequences:

ƒ

The device can be destroyed when the input voltage is too high.

Protective measures:

ƒ

Observe the max. permissible input voltage.

ƒ

Professionally fuse the device on the input side against voltage
fluctuations and voltage peaks.

(

Stop!

Short circuit and static discharge

The device contains components which are endangered in the case
of short circuit or static discharge.

Possible consequences:

ƒ

The device or parts of it are destroyed.

Protective measures:

ƒ

When working on the device, always switch off the voltage
supply (mains and a possibly mounted UPS). This particularly
applies to the following:
– Before opening the housing.
– Before connecting / removing connectors.
– Before plugging in / plugging out modules.

ƒ

All persons handling printed circuit boards have to take account
of ESD measures.

ƒ

Contacts of connectors may not be touched.

ƒ

Printed circuit boards may be touched only at places free from
electrical contacts and may be placed only on appropriate
materials (e.g. on ESD packaging or conductive foam material).

ƒ

Printed circuit boards may only be transported and stored in ESD
packaging.